After entering the mode, the joystick is moved right or left to select the character to
be changed. The selected character is identified by a box with a question mark
inside it. The first line of the video monitor display indicates the code number of the
character selected. Move the joystick up or down to step through the Character
ROM Table, or enter the character's number identified in the tables via the numeric
keypad, then press
[Enter]
. Once the monitor title has been set, press
[Enter]
to store
it to memory. If using the LTC 8555 Series keyboard, press [
User]
to exit the mode.
The user may select between this monitor message and the status display by using
the User 5 Function described above.
User Function 18 - Print Sequence
Use this function to print the contents of a programmed sequence. Use the joystick
to select the desired sequence, then press
[Enter]
to print it to the printer port. Only
those sequences currently existing in memory will be shown in the list. If using the
LTC 8555 Series keyboard, press
[User]
to exit.
User Function 19 - Select Alarm Response
Use this function to reset the system alarm configuration tables to one of these pre-
defined alarm response modes:
BASIC
,
AUTOBUILD
, or
SEQUENCE & DISPLAY
.
Move the joystick up or down to select the desired mode, then enter your user pass-
word on the numeric keypad. Press
[Enter]
to update the alarm system. If using the
LTC 8555 Series keyboard, press
[User]
to exit.
NOTE
Existing alarm configuration data will be lost when mode is changed.
User Function 20 - Select Printer Verbosity
Use this function to select between print modes; Limited Printing and Full Printing.
This selection determines the amount of information printed during alarm process-
ing. Both modes print alarm activation and deactivation messages, but Full Printing
goes into much more detail. Use the joystick to select the desired mode, then press
[Enter]
. If using the LTC 8555 Series keyboard, press
[User]
to exit without chang-
ing the print mode.
User Function 21 - Designate Alarm Monitor Type
Use this function to designate the monitor currently controlled by the keyboard as
either a
STEP
monitor or a
REVIEW
monitor. This function can only be used in the
predefined
SEQUENCE & DISPLAY
alarm response mode (see
ALARM INFORMA-
TION
section) to select which monitor is the
STEP
(also called
SEQUENCE
) moni-
tor, and which is the
REVIEW
(also called
DISPLAY
) monitor. To designate a
monitor as the
STEP
or
REVIEW
monitor, enter User Function 21, then move the
joystick up or down to select the monitor type. Enter your password on the key-
board and press
[Enter]
. If using the LTC 8555 Series keyboard, press
[User]
to exit.
After selecting new
STEP
and
REVIEW
monitors, the previous ones may be dis-
armed (Arm/Disarm Monitor instructions).
User Function 22 - Select Control Code Format
This function designates whether variable speed pan/tilt and zoom commands are
enabled (Factory Default Setting). In most cases, there is no need to disable this
function. Move the joystick up or down to select the desired setting, then press
[Enter]
. If using the LTC 8555 Series keyboard, press
[User]
to exit.
Summary of Contents for LTC 8016/90
Page 2: ...EN ii Bosch Security Systems December 13 2005 ...
Page 79: ...Replacement of Memory Backup Batteries EN 69 Figure 15 LTC 8500 Character ROM Table ...
Page 101: ...Product Instruction Manual Important Safeguards EN 91 ...
Page 102: ...Product Instruction Manual Safety Precautions EN 92 Bosch Security Systems December 13 2005 ...
Page 103: ...Product Instruction Manual FCC ICES Information EN 93 ...