Arm/Disarm All Alarms
Press [
Alarm Control]
, located on the main Allegiant menu screen to enter the menu
screen containing these options. When using the IntuiKey keyboard:
•
To arm all alarms currently controlled on the monitor, press [
Arm All Alarms]
.
•
To disarm all alarms, press [
Disarm All Alarms]
.
When using the LTC 8555 Series keyboard:
•
To arm all alarms, press [
User]
. Then, press [
Alarm]
and then press
[ON]
.
•
To disarm all alarms, press
[OFF]
.
Arm/Disarm Monitor
When using the IntuiKey keyboard:
•
Press [
Alarm Control]
, located on the main Allegiant menu screen to enter the
screen with these options.
•
To arm the monitor currently controlled, press [
Arm Monitor]
.
•
To disarm the monitor, press [
Disarm Monitor]
.
When using the LTC 8555 Series keyboard:
•
To arm the monitor, press [
User].
Then, press [
Monitor]
and then press
[ON]
to
arm all alarms.
•
To disarm all alarms, press
[OFF]
.
NOTE
Alarm video appears on a monitor only if the monitor is armed and the alarm is
armed for that monitor. The monitor status display (if enabled) will show
M
A
(monitor armed).
Alarms Acknowledgement
Bell
[Ack]
is provided so system operators can respond to alarms from the keyboard.
Press
Bell [Ack]
when the keyboard is beeping (due to an alarm condition) to silence
the beeper. Depending on alarm configuration programming, subsequent pressing
of
Bell [Ack]
either clears an alarm video from the monitors or has no effect.
16.6 Sequence Control
Load/Clear a Sequence
To load a previously programmed sequence to run on your monitor, press
Load
Sequence [Seq]
, enter the desired sequence number (1 to 60), then press
[Enter]
.
Note that loading a sequence does not automatically start the sequence running.
Since sequences may be programmed to use more than one monitor, all required
monitors must be available. If a sequence is already on a monitor, the operator who
loaded it originally (or an operator with a higher priority) is permitted to load a new
sequence on the monitor(s). Others will receive an error message.
To clear a monitor sequence, press
Load sequence [Seq]
, then press
[Enter]
. Only
the operator who originally loaded it (or an operator with a higher priority) is per-
mitted to clear a monitor sequence. Others will receive an error message. If enabled,
the status display area of the monitor indicates the sequence number in the appro-
priate location. If no sequence is currently loaded,
00
is displayed.
Summary of Contents for LTC 8016/90
Page 2: ...EN ii Bosch Security Systems December 13 2005 ...
Page 79: ...Replacement of Memory Backup Batteries EN 69 Figure 15 LTC 8500 Character ROM Table ...
Page 101: ...Product Instruction Manual Important Safeguards EN 91 ...
Page 102: ...Product Instruction Manual Safety Precautions EN 92 Bosch Security Systems December 13 2005 ...
Page 103: ...Product Instruction Manual FCC ICES Information EN 93 ...