EFAS is able to activate a preprogrammed activity (
,
or
) for the driver and/or co-driver when the ignition is turned on or off.
Programming of the activities after ignition OFF/ON is only possible in the COMPANY or CALIBRATION operating modes, i.e. with
a company smart-card or workshop smart-card inserted.
The function to automatically switch activity can also be deactivated, i.e. when the ignition is turned on/off, the current activity
setting for the driver/co-driver is retained.
Select the following setting:
OK
g
Settings
g
Activity Ignition OFF/ON
The current setting is displayed:
Figure 41 — Display of activity on ignition off/on
If ”–” is displayed, the automatic activity switch is deactivated, i.e. when the ignition is turned on/off, the current activity setting
will be retained.
Use the cursor keys
or
to select one of the following settings:
–
Maintain driver activity
Driver in rest period
Driver in work period
Driver in standby period
Figure 42 — Activity setting on ignition off/on
Press
OK
to adopt the driver activity after Ignition ON. This takes you to the next input mask. In the same way, enter the desired
activity in the following three input masks:
y
Activity for driver Ignition OFF
y
Activity for co-driver Ignition ON
y
Activity for co-driver Ignition OFF
On confirmation of the last activity with the key
OK
, the settings are stored in EFAS.
7.3
Blocking first generation tachograph cards
In CALIBRATION mode, the function „
GEN1 blocked
“ can be activated via the menu. After execution it will cause EFAS to
block or no longer accept first generation tahograph cards. For safety reasons, two safety checks must be confirmed by the
workshop. If the second security prompt is also acknowledged with
YES
, the data of the workshop carrying out the work are
stored and any further use of tachograph cards of the 1st generation will be refused.
Select
OK
g
Installation
g
GEN1 blocked
Note
The function „
GEN1 blocked
“ is an irreversible function that is no longer displayed in the EFAS menu once
it has been executed.
7.4
Remote Data Downloading
After selecting the menu item, the remote data download function (remote readout from the mass memory of the tachograph)
can be switched on or off. If the function is switched on, the communication via CAN-C to the FMS-Box is enabled.
Select
OK
g
Installation
g
Remote Data Download
Summary of Contents for Intellic EFAS-4.10
Page 1: ...Powered by Workshop Manual Smart Tachograph EFAS 4 10 4 11 ...
Page 2: ......
Page 4: ......
Page 6: ......