background image

Whilst it is always our intention to fully assist, it is essential to recognise that all information given by the company in response to an enquiry of any nature is provided in good faith and based 

upon the information provided with the enquiry. We recommend that advice should always be checked with your installer or contract partner. Consequently, the company cannot be held 

responsible for any liability relating to the use or repetition of such information or part thereof. In addition, whilst making every reasonable effort to monitor the performance and quality of 

our supply, installation and service network, we do not accept responsibility for the workmanship or operation of any third party company that the company may have promoted either in 

conversation, e-mail, or other communication. Similarly, the views and opinions expressed in communication with individuals within the company may not reflect that of the business as a whole.

 

You can find this, and all issued technical bulletins on the Worcester website at: 

worcester-bosch.co.uk/tb 

or 

worcester-bosch.ie/tb

 

15

 

Worcester, Bosch Group, Cotswold Way, Warndon, Worcester WR4 9SW Technical Services: 0330 123 3366 [email protected]

 

Bosch Flue and Ventilation Quick Reference Guide 2022

 

 

 

 

U and 5U (uncorrected chimney height) for boilers in cascade 

Boiler Combinations

 

kW input

 

 U (m)

 

5U (m)

 

2 x GC 7000 WP 50kW

 

95 

0.370 

1.85 

3 x GC 7000 WP 50kW

 

142.5 

0.472 

2.36 

4 x GC 7000 WP 50kW

 

190 

0.561 

2.81 

5 x GC 7000 WP 50kW

 

237.5 

0.642 

3.21 

6 x GC 7000 WP 50kW

 

285 

0.716 

3.58 

2 x GC 7000 WP 65kW

 

128.6 

0.444 

2.22 

3 x GC 7000 WP 65kW

 

192.9 

0.566 

2.83 

4 x GC 7000 WP 65kW

 

257.2 

0.673 

3.37 

5 x GC 7000 WP 65kW

 

321.5 

0.769 

3.85 

6 x GC 7000 WP 65kW

 

385.8 

0.858 

4.29 

1 x GC 7000 WP 85kW

 

82 

0.339 

1.69 

2 x GC 7000 WP 85kW

 

164 

0.514 

2.57 

3 x GC 7000 WP 85kW

 

246 

0.655 

 3.28 

4 x GC 7000 WP 85kW

 

328 

0.779 

3.89 

5 x GC 7000 WP 85kW

 

410 

0.890 

4.45 

6 x GC 7000 WP 85kW

 

492 

0.993 

4.97 

1 x GC 7000 WP 100kW

 

96.5 

0.374 

1.87 

2 x GC 7000 WP 100kW

 

193 

0.567 

2.84 

3 x GC 7000 WP 100kW

 

289.5 

0.723 

3.62 

4 x GC 7000 WP 100kW

 

386 

0.859 

4.30 

5 x GC 7000 WP 100kW

 

482.5 

0.982 

4.91 

6 x GC 7000 WP 100kW

 

579 

1.095 

5.48 

1 x GC 7000 WP 125kW

 

118.1 

0.422 

2.11 

2 x GC 7000 WP 125kW

 

236.2 

0.639 

3.20 

3 x GC 7000 WP 125kW

 

354.3 

0.816 

4.08 

4 x GC 7000 WP 125kW

 

472.4 

0.969 

4.85 

5 x GC 7000 WP 125kW

 

590.5 

1.108 

5.54 

6 x GC 7000 WP 125kW

 

708.6 

1.236 

6.18 

1 x GC 7000 WP 145kW

 

140.1 

0.467 

2.34 

2 x GC 7000 WP 145kW

 

280.2 

0.709 

3.54 

3 x GC 7000 WP 145kW

 

420.3 

0.904 

4.52 

4 x GC 7000 WP 145kW

 

560.4 

1.074 

5.37 

5 x GC 7000 WP 145kW

 

700.5 

1.228 

6.14 

6 x GC 7000 WP 145kW

 

840.6 

1.370 

6.85 

 

CO Detection for cascade flues systems 

 

Bosch has taken the decision to require the mandatory use of CO detection for boiler systems using a cascade flue system where there is 

more than one appliance. CO detection must result in a boiler shut off and prevent CO exposure. 

 

With our GC 7000 WP range, all Bosch Cascade base flue kits contain a CO detector for on-site wiring into our CC8313 controller or 

MC400 Cascade controller, where these controllers are not used due to controls from a BMS system it is still a requirement that the BMS 

has some form of CO detection thus activating a boiler shut off. The detection threshold level should be no higher than 50ppm. 

 

Failure to fit a form of CO detection to a Cascade will result in a failed commissioning. 

 

For more information on CO detection please see technical bulletin: TB 0164 a (07/2022) 

 

 

 

 

 

 

 

 

Please refer to manufacturer’s instructions for more information on flue requirements.

 

Summary of Contents for GC 7000 WP

Page 1: ...GC 7000 WP Flue and Ventilation Quick Reference Guide 2022 ...

Page 2: ...g boilers only Please note Groups of boilers exceeding 70 kW net are covered by IGEM UP 10 Edition 4 and BS6644 2011 Total rated net input must not exceed 70 kW Natural ventilation for open flued appliances installed within a room BOILER TYPE NET HEAT INPUT VENTILATION ROUTE ROOM 1 ROOM 2 ROOM 3 GC 7000 WP 50 kW 47 5 kW Ventilation for room containing appliance 203 cm N A N A Ventilation through 1...

Page 3: ...e of 15ºC Open flued gas appliance installed within a plant room SYSTEM TYPE GRILLE LOCATION WITH 600MM CLEARANCE FROM ANY OBSTRUCTION HEATING OR HWS 50 SUMMER USAGE HEATING OR HWS 75 SUMMER USAGE HEATING OR HWS 100 SUMMER USAGE High level free area cm per kW net heat input cm 2 3 4 Low level free area cm per kW net heat input cm 4 5 6 Open flued gas appliance installed within an enclosure natural...

Page 4: ...eviewsandopinionsexpressedincommunicationwithindividualswithinthecompanymaynotreflectthatofthebusinessasawhole You can find this and all issued technical bulletins on the Worcester website at worcester bosch co uk tb or worcester bosch ie tb 3 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Positioning of ventilation withi...

Page 5: ...all issued technical bulletins on the Worcester website at worcester bosch co uk tb or worcester bosch ie tb 4 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 An example of ventilation distribution fora plant room that has louvered doors and additional high level ventil...

Page 6: ...co uk tb or worcester bosch ie tb 5 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 Air supply and ventilation within a commercial installation continued quick referencing guide to meet IGEM UP 10 Edition 4 and BS6644 2011 Mechanical ventilation for appliances without d...

Page 7: ...o uk tb or worcester bosch ie tb 6 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 Flue termination The information in this section is based on fluing not exceeding 333 kW aggregated for anything over 333 kW please refer to vertical open flue termination See page 11 Ple...

Page 8: ...300mm above below or either side of an opening door air vent or opening window 10 600mm diagonally to an opening door air vent or opening window 11 300mm to an internal or external corner 12 2 000mm below a Velux window 600mm above or to either side of the Velux window 13 400mm from a pitched roof or in regions with heavy snow fall 500mm 14 500mm clearance to any vertical structure on a roof 600mm...

Page 9: ...y may have promoted either in conversation e mail orothercommunication Similarly theviewsandopinionsexpressedincommunicationwithindividualswithinthecompanymaynotreflectthatofthebusinessasawhole You can find this and all issued technical bulletins on the Worcester website at worcester bosch co uk tb or worcester bosch ie tb 8 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Se...

Page 10: ...website at worcester bosch co uk tb or worcester bosch ie tb 9 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 Horizontal flue terminal distances from openings within a wall When multiple horizontal room sealed flues terminate on the same wall a clearance zone will need...

Page 11: ...Worcester WR4 9SW Technical Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 Plume Management Kit termination clearances The plume terminal outlet must follow the conditions outlined in Figure 9 When directing the plume discharge outlet please refer to the tables below for minimum distance from an opening This is to prevent products of comb...

Page 12: ... required figures within IGEM UP 10 Edition 4 Figure 11B page 45 distance Y from figure 5 above is used to assess this risk Figure 12 page 46 formula to calculate distance G 19 32 x Net head input kW 647 59 5U the distance for GC 7000 WP appliances can be found on page 12 of this document Section 1 Type C room sealed appliances with net heat exceeding 70kW and not exceeding 333kW low level flue di...

Page 13: ...either in conversation e mail orothercommunication Similarly theviewsandopinionsexpressedincommunicationwithindividualswithinthecompanymaynotreflectthatofthebusinessasawhole You can find this and all issued technical bulletins on the Worcester website at worcester bosch co uk tb or worcester bosch ie tb 12 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Technical Services 0330 123 336...

Page 14: ... group of individual flues terminate close to each other and within 5U they must be aggregated and the value used for the flue height calculation Flue termination height above structures distance X for appliances up to 333 kW Refer to Figure 15 For terminals fitted to a pitched roof the end piece termination as shown in Figure 15 should be at least 1 5m from the roof surface when measured horizont...

Page 15: ...cal Services 0330 123 3366 technical advice uk bosch com Bosch Flue and Ventilation Quick Reference Guide 2022 Open flue terminations above 333kW net input When a flue configuration is rated over 333 kW net heat input then according to the Clean air act local authorities must be informed to gain approval of the Chimney height This is to ensure that flue discharges do not cause nuisance to others o...

Page 16: ...85 6 x GC 7000 WP 65kW 385 8 0 858 4 29 1 x GC 7000 WP 85kW 82 0 339 1 69 2 x GC 7000 WP 85kW 164 0 514 2 57 3 x GC 7000 WP 85kW 246 0 655 3 28 4 x GC 7000 WP 85kW 328 0 779 3 89 5 x GC 7000 WP 85kW 410 0 890 4 45 6 x GC 7000 WP 85kW 492 0 993 4 97 1 x GC 7000 WP 100kW 96 5 0 374 1 87 2 x GC 7000 WP 100kW 193 0 567 2 84 3 x GC 7000 WP 100kW 289 5 0 723 3 62 4 x GC 7000 WP 100kW 386 0 859 4 30 5 x ...