DICENTIS
Installation material and tools | en
45
Bosch Security Systems B.V.
Hardware Installation Manual
2021.01 | V2.2 |
Pin #
Function
Specifications
Description
1
Switch to set the
booth on-air LED on/
off
50 V/1 A potential free
contact
Galvanic separated
OUTPUT
2
OUTPUT
3
4
5
Input for an external
telephone system
ringing indicator
inactive: < 1 VDC
active: > 3 VDC
max.: 24 VDC
Galvanic separated
INPUT Negative (
-
)
6
INPUT Positive (
+
)
7
Input for an external
system for warning
indicator
inactive: < 1 VDC
active: > 3 VDC
max.: 24 VDC
Galvanic separated
INPUT Negative (
-
)
8
INPUT Positive (
+
)
Tab. 5.8: Connector pinout
Note:
the female plug to be used with the 8-pin connector is supplied pre-assembled with the
product. You will need to make the wire connections, which only require simple push-in action
to lock.
Wiring
The connection to the Phoenix connector has to be made using ferrules.
The tables below give more details on the connection.
Conductor cross section max.
(solid and flexible)
1.5 mm
2
Conductor cross section flexible,
with ferrule without plastic sleeve
max.
1.5 mm
2
Conductor cross section flexible,
with ferrule with plastic sleeve
max.
0.75 mm
2
Tab. 5.9: Connection data
Ferrules without insulating collar
(according to DIN 46228-1)
Cross section: 0.22 mm
2
to 1.5 mm
2
Length: 5 mm to 10 mm
Tab. 5.10: Specifications for ferrules