Key to symbols and safety instructions | 3

1

Key to symbols and safety instructions

1.1

Explanation of symbols

Warning symbols

Keywords at the start of a warning indicate the type and 
seriousness of the ensuing risk if measures to prevent the risk 
are not taken.

The following keywords are defined and can be used in this 
document:

DANGER: 

DANGER

 indicates a situation that will result in severe injury or 

death.

WARNING: 

WARNING

 indicates a situation that could result in severe 

injury or death.

CAUTION: 

CAUTION

 indicates a situation that could result in minor to 

medium injury.

NOTICE: 

NOTICE

 indicates a situation that could result in damage to 

property or equipment.

Important information

The info symbol indicates important information where there is 
no risk to people or property.

Additional symbols

Table 1  

1.2

General safety instructions

These installation instructions are intended for plumbers, 
heating engineers and electricians.
▶ Read the installation instructions (heat sources, modules, 

etc.) before installation.

▶ Observe the safety instructions and warnings.
▶ Observe national and regional regulations, technical rules 

and guidelines.

▶ Record all work carried out.

H

Determined use

▶ Only use the product to control solar heating systems in 

domestic or light commercial applications.

Any other use is considered inappropriate. We take no 
responsibility for damage caused through incorrect use.

H

Installation, commissioning and maintenance

Installation, commissioning and maintenance must only be 
carried out by a competent person.

▶ Never install the product in wet rooms.
▶ Only use genuine spare parts.

H

Electrical work

Electrical work must only be carried out by a qualified 
electrician.

▶ Before starting electrical work: 

– Isolate the mains electrical supply and secure against 

reconnection.

– Using suitable means, test that the mains voltage is 

disconnected.

▶ Never connect the product to mains voltage.
▶ Also observe the connection diagrams of other system 

components.

H

Handover to the user

When handing over the solar heating system, instruct the user 
in its operation and operating conditions.

▶ Explain the operation - with particular emphasis on all 

safety-related actions.

▶ Explain that conversions and repairs must only be carried 

out by a competent person.

▶ Point out the need for inspections and maintenance for safe 

and optimal operation.

▶ The installation and operating instructions must be given to 

the user for safekeeping.

H

Damage caused by frost

The solar system can freeze if it is switched off:
▶ Observe the notices regarding frost protection.

Symbol Meaning

a step in an action sequence

 

a reference to a related part in the document

a list entry

a list entry (second level)

Summary of Contents for CS 200

Page 1: ...6720850722 2015 06 Installation instructions for installers Solar controller CS 200 0010005426 001 EMS 2 ...

Page 2: ...in the display 7 4 3 Operating the service menu 8 4 4 Overview of the service menu 8 5 Commissioning 8 5 1 Overview of the commissioning steps 9 5 2 General commissioning of the solar controller 9 5 3 Systemcommissioningwiththeconfiguration wizard 9 5 3 1 Commissioning the solar heating system 9 5 3 2 Commissioning the freshwater system 10 5 3 3 Commissioning the transfer station 11 5 4 Additional...

Page 3: ...olar heating systems in domestic or light commercial applications Any other use is considered inappropriate We take no responsibility for damage caused through incorrect use H Installation commissioning and maintenance Installation commissioning and maintenance must only be carried out by a competent person Never install the product in wet rooms Only use genuine spare parts H Electrical work Elect...

Page 4: ...mation in these instructions 2 2 Important information on use CAUTION Risk of injury through scalding If the DHW temperature is set to 60 C discharging unmixed domestic hot water can lead to serious scalding Set the temperature for normal operation to 60 C Do not discharge domestic hot water unmixed Install a mixer Only products from Bosch may be used within the BUS system The installation room mu...

Page 5: ...ature is set to 60 C discharging unmixed domestic hot water can lead to serious scalding Set the temperature for normal operation to 60 C Do not discharge domestic hot water unmixed Install a mixer WARNING Risk to life from electric shock Touching live parts can result in an electric shock Beforeinstallingaccessories Disconnectthepowersupply to the heat source building management system and any ot...

Page 6: ...ries or in a star pattern To avoid inductive interference Make sure all low voltage cables are routed separately from mains voltage cables min clearance 100 mm In the case of external inductive interferences e g from photovoltaic systems use shielded cables e g LIYCY and earth the shield on one side The shield should be connected to the building s earthing system e g to a free earth conductor term...

Page 7: ... change of the temperature displayed in the standard display 4 menu key Opens the main menu hold to open the service menu 5 info key Displays the info menu for information about the current selection 6 Back key Returns to previous menu or discards a value press briefly returns to the standard display hold down 7 Rotary control knob Selects turn and Confirms press 4 2 Overview of the symbols in the...

Page 8: ...ding operating mode Press the rotary control knob to activate the input field for the switching time or the operating mode Turn the rotary control knob to change the setting value Confirming or rejecting the change Rejecting the change Press the rotary control knob to activate the marked entry or to confirm the change Turn the rotary control knob to highlight Continue and press the rotary control ...

Page 9: ...enu and the factory defaults to the current system Perform system commissioning Chapter 5 3 5 3 System commissioning with the configuration wizard ThesolarcontrollerautomaticallyrecogniseswhichBUSnodes e g modules are installed in the system The configuration wizard adjusts the menu and the factory defaults The system analysis may take up to one minute After the configuration wizard has performed ...

Page 10: ...r setting Isthesolarsystemfilledand vented Do you want to start the solar system now Yes No Menu item Start configuration wizard Menu item Question Answer setting Check before starting the configuration wizard Module installed and address set Temperature sensor installed System charged and vented Start the configuration wizard Yes No Operating mode Question Answer setting Which system is installed...

Page 11: ...onlybeswitchedofffor maintenance work for example Disconnect power from the entire system and all BUS nodes After a prolonged power failure or extended period of idleness the date and time may need to be reset All other settings are retained permanently 7 Service menu The menu of the solar controller is adapted to your system automatically Somemenuitemsareonlyavailableifthesystem has been set up a...

Page 12: ...iff heat ex Frost prot temp heat ex Central heating backup Start diff ctrl heat back Stop diff ctrl heat back Max mixer temp CH Mixer runtime CH Solar yield optimisation Gross collector area 1 Type collector array 1 Climate zone Reset solar yield Reset solar optimisation Reset elapsed times Set temp Double Match F Glycol content Transfer Transfer start diff Transfer stop diff Start diff diff ctrll...

Page 13: ...gs for the transfer system 7 3 Settings for freshwater systems If a freshwater system with extended function is installed correspondingmenusandmenuitemsareavailable Themenus of the freshwater system are described in detail in the operating instructions of the used module In the DHW settings menu with all freshwater systems the sub menus listed in Tab 11 are available Table 11 General settings for ...

Page 14: ... depend on the system that has been installed Observe the technical documentation for modules and other system components 7 4 3 Fault displays The current faults and the fault history can be called up in this menu Table 12 Information in the fault display menu 7 4 4 System information The software versions of the BUS nodes installed in the system can be called up in this menu 7 4 5 Maintenance You...

Page 15: ...his function is not performed if the domestic hot water has already reached the set temperature within the last 12 hours due to solar heating The daily heat up starts automatically at the set time according to the time set in the solar controller 9 Troubleshooting Table 16 During installation enter the ID number of the solar controller here A fault in the system is indicated on the display of the ...

Page 16: ...Cause Corrective measure Checkconfiguration setaddress at the module The selected setting requires a solar module Change configuration Check the EMS connecting lead to the solar module for damage BUS voltage at the solar module must be between 12 15 V DC Replace damaged cables Solar module defective Replace the module Fault code sub code cause or fault description A51 6021 Collector temperature se...

Page 17: ...6720850722 2015 06 CS 200 Environmental protection and disposal 17 Batteries must not be disposed together with your household waste Used batteries must be disposed of in local collection systems ...

Page 18: ......

Page 19: ......

Page 20: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...

Reviews: