6720850722 (2015/06)
CS 200
Shutdown / switching off | 11
5.3.3 Commissioning the transfer station
Table 8
Settings in the Commissioning menu
5.4
Additional settings at commissioning
Some settings are only available if the system is designed and
configured accordingly. For more details refer to the MS 100/
MS 200 technical documentation.
▶ Check the settings in the service menu (
Chapter 7,
page 11 and installation instructions MS 100/MS 200).
5.5
Performing function tests
The function tests can be accessed via the diagnosis menu. The
available menu items are strongly dependent on the system
installed. Under this menu the following can be tested, for
example:
Solar pump
:
On
/
Off
(
Chapter 7.4.1, page 14).
5.6
Check monitored values
The monitored values can be accessed via the
Diagnosis
menu
(
Chapter 7.4.2, page 14).
5.7
System handover
▶ Enter the contact details of the responsible installer in the
Diagnosis
menu >
Maintenance
>
Contact address
, e.g.
company name, phone number and address or e-mail
address (
Chapter 7.4.5, page 14).
▶ Explain to the customer how the solar controller and the
accessories work and how to operate them in accordance
with best practice.
▶ Inform the customer about the selected settings.
We recommend to hand over these installation instructions to
the end user.
6
Shutdown / switching off
The solar controller is powered via the BUS interface and is
always switched on. The system should only be switched off for
maintenance work, for example.
▶ Disconnect power from the entire system and all BUS
nodes.
After a prolonged power failure or extended period of idleness,
the date and time may need to be reset. All other settings are
retained permanently.
7
Service menu
The menu of the solar controller is adapted to your system
automatically. Some menu items are only available if the system
has been set up accordingly and the solar controller has been
set correctly. The menu items are only displayed in systems in
which the corresponding system components are installed,
e.g. two collector arrays. The corresponding menu items and
settings can be found in the respective operating instructions.
Information about the operation of the service menu are
summarised in Chapter 4, starting on page 7.
Menu:
Service menu
Commissioning
– Start configuration wizard?
– Operating mode
– Extension module
– Change solar configuration
Menu item
Start configuration wizard?
Question
Answer / setting
Check before starting the configuration wizard:
•
Module installed and address set?
•
Temperature sensor installed?
•
System charged and vented?
Start the configuration
wizard?
Yes | No
Operating mode
Question
Answer / setting
Which system is installed?
Is the coding switch
correspondingly set at the
module?
Solar | DHW (Freshwater) |
Transfer system
Change transfer configuration
Question
Answer / setting
Is the transfer system
correctly configured with all
functions and additional
functions?
Graphic configuration of the
transfer system
Max. DHW temp.
Question
Answer / setting
What is the maximum
temperature of the DHW?
60 ... 80 °C