▶ Due to the additional functions, e.g. DHW heating or pump 

anti-seizure protection, the system should always be left 
on.

▶ Correct any faults immediately.

2

Product Description

2.1

Product description

The CS 200 must be used in conjunction with the 
MS 200 to control a Solar heating system, in certain 
cases an MS 100 may also be combined.

After operating for 90 minutes, the solar controller has a 
power reserve of at least 8 hours. If the power failure lasts 
longer than the power reserve, the time and date will be 
deleted. All other settings are saved.

The functional scope and thus the menu structure of the 
solar controller are determined by the structure of the 
system. These instructions describe the maximum 
functional scope of the equipment. Your attention is drawn 
to the importance of the system structure in the relevant 
places. The adjustment ranges and default settings may 
differ from the information in these instructions.

2.2

Important information on use

CAUTION: 

 Risk of injury through scalding!

If the DHW temperature is set to > 60 °C, discharging unmixed 
domestic hot water can lead to serious scalding.

▶ Set the temperature for normal operation to < 60 °C.
▶ Do not discharge domestic hot water unmixed.
▶ Install a mixer.

Only products from Bosch may be used within the BUS 
system.

The installation room must be appropriate for IP20 rating.

2.3

Declaration of Conformity

The design and operation of this product comply 
with European Directives and the supplementary 
national requirements. Conformity has been 

demonstrated by the CE marking .

You can ask for a copy of the Declaration of Conformity for this 
product. Please refer to the contact address on the back cover 
of these instructions.

2.4

Scope of delivery

Fig. 1  

Scope of delivery

[1]

Wall-mounting plate

[2]

Solar controller

[3]

Installation material

[4]

Technical documentation

2.5

Technical specifications

Fig. 2  

Dimensions in mm

Scope of delivery

 Chapter 2.4, page 4

Dimensions

150   ×  90   ×  25  mm 
(

 Fig. 2)

Nominal voltage

10 - 24 V DC

0010005428-001

i

i

1

4

2

3

0010005429-001

auto

man

fav

menu

info

123

25

32

101

Summary of Contents for CS 200

Page 1: ...6720850722 2015 06 Installation instructions for installers Solar controller CS 200 0010005426 001 EMS 2 ...

Page 2: ...in the display 7 4 3 Operating the service menu 8 4 4 Overview of the service menu 8 5 Commissioning 8 5 1 Overview of the commissioning steps 9 5 2 General commissioning of the solar controller 9 5 3 Systemcommissioningwiththeconfiguration wizard 9 5 3 1 Commissioning the solar heating system 9 5 3 2 Commissioning the freshwater system 10 5 3 3 Commissioning the transfer station 11 5 4 Additional...

Page 3: ...olar heating systems in domestic or light commercial applications Any other use is considered inappropriate We take no responsibility for damage caused through incorrect use H Installation commissioning and maintenance Installation commissioning and maintenance must only be carried out by a competent person Never install the product in wet rooms Only use genuine spare parts H Electrical work Elect...

Page 4: ...mation in these instructions 2 2 Important information on use CAUTION Risk of injury through scalding If the DHW temperature is set to 60 C discharging unmixed domestic hot water can lead to serious scalding Set the temperature for normal operation to 60 C Do not discharge domestic hot water unmixed Install a mixer Only products from Bosch may be used within the BUS system The installation room mu...

Page 5: ...ature is set to 60 C discharging unmixed domestic hot water can lead to serious scalding Set the temperature for normal operation to 60 C Do not discharge domestic hot water unmixed Install a mixer WARNING Risk to life from electric shock Touching live parts can result in an electric shock Beforeinstallingaccessories Disconnectthepowersupply to the heat source building management system and any ot...

Page 6: ...ries or in a star pattern To avoid inductive interference Make sure all low voltage cables are routed separately from mains voltage cables min clearance 100 mm In the case of external inductive interferences e g from photovoltaic systems use shielded cables e g LIYCY and earth the shield on one side The shield should be connected to the building s earthing system e g to a free earth conductor term...

Page 7: ... change of the temperature displayed in the standard display 4 menu key Opens the main menu hold to open the service menu 5 info key Displays the info menu for information about the current selection 6 Back key Returns to previous menu or discards a value press briefly returns to the standard display hold down 7 Rotary control knob Selects turn and Confirms press 4 2 Overview of the symbols in the...

Page 8: ...ding operating mode Press the rotary control knob to activate the input field for the switching time or the operating mode Turn the rotary control knob to change the setting value Confirming or rejecting the change Rejecting the change Press the rotary control knob to activate the marked entry or to confirm the change Turn the rotary control knob to highlight Continue and press the rotary control ...

Page 9: ...enu and the factory defaults to the current system Perform system commissioning Chapter 5 3 5 3 System commissioning with the configuration wizard ThesolarcontrollerautomaticallyrecogniseswhichBUSnodes e g modules are installed in the system The configuration wizard adjusts the menu and the factory defaults The system analysis may take up to one minute After the configuration wizard has performed ...

Page 10: ...r setting Isthesolarsystemfilledand vented Do you want to start the solar system now Yes No Menu item Start configuration wizard Menu item Question Answer setting Check before starting the configuration wizard Module installed and address set Temperature sensor installed System charged and vented Start the configuration wizard Yes No Operating mode Question Answer setting Which system is installed...

Page 11: ...onlybeswitchedofffor maintenance work for example Disconnect power from the entire system and all BUS nodes After a prolonged power failure or extended period of idleness the date and time may need to be reset All other settings are retained permanently 7 Service menu The menu of the solar controller is adapted to your system automatically Somemenuitemsareonlyavailableifthesystem has been set up a...

Page 12: ...iff heat ex Frost prot temp heat ex Central heating backup Start diff ctrl heat back Stop diff ctrl heat back Max mixer temp CH Mixer runtime CH Solar yield optimisation Gross collector area 1 Type collector array 1 Climate zone Reset solar yield Reset solar optimisation Reset elapsed times Set temp Double Match F Glycol content Transfer Transfer start diff Transfer stop diff Start diff diff ctrll...

Page 13: ...gs for the transfer system 7 3 Settings for freshwater systems If a freshwater system with extended function is installed correspondingmenusandmenuitemsareavailable Themenus of the freshwater system are described in detail in the operating instructions of the used module In the DHW settings menu with all freshwater systems the sub menus listed in Tab 11 are available Table 11 General settings for ...

Page 14: ... depend on the system that has been installed Observe the technical documentation for modules and other system components 7 4 3 Fault displays The current faults and the fault history can be called up in this menu Table 12 Information in the fault display menu 7 4 4 System information The software versions of the BUS nodes installed in the system can be called up in this menu 7 4 5 Maintenance You...

Page 15: ...his function is not performed if the domestic hot water has already reached the set temperature within the last 12 hours due to solar heating The daily heat up starts automatically at the set time according to the time set in the solar controller 9 Troubleshooting Table 16 During installation enter the ID number of the solar controller here A fault in the system is indicated on the display of the ...

Page 16: ...Cause Corrective measure Checkconfiguration setaddress at the module The selected setting requires a solar module Change configuration Check the EMS connecting lead to the solar module for damage BUS voltage at the solar module must be between 12 15 V DC Replace damaged cables Solar module defective Replace the module Fault code sub code cause or fault description A51 6021 Collector temperature se...

Page 17: ...6720850722 2015 06 CS 200 Environmental protection and disposal 17 Batteries must not be disposed together with your household waste Used batteries must be disposed of in local collection systems ...

Page 18: ......

Page 19: ......

Page 20: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...

Reviews: