AutoDome Junior HD
Installing a Pipe Mount | en
71
Bosch Security Systems, Inc.
Installation Manual
F.01U.275.803 | 6.0 | 2012.11
Figure 7.4
O-ring and retaining ring placement for outdoor
installation
a.
Thread the 21.82 mm I.D. by Ø3.00 mm O-ring (item 1,
above) onto the lower pipe threads.
b.
Secure the retaining ring gasket (item 2, above) to the
dome cap with the three (3) M3 – .5 x 6 Phillips flat
head machine screws. Ensure that the side of the
retaining ring with the counter-sunk screw holes is
facing you.
8.
Secure the flange using four (4) appropriate user-provided
fasteners such as Moly or Toggle bolts.
Outdoor Installation:
Place the flat gasket (item 1, below)
between the flange and the surface before securing.
1
O-ring; 21.82 mm I.D. by Ø3.00 mm
2
Dome Cap
3
Retaining ring with gasket
4
M3 – .5 x 6 Phillips flat head machine screws