AUTODOME inteox 7000i - 2MP (in-ceiling)
Connection | en
29
Bosch Security Systems
Installation Manual
2021-08 | 1.4 |
2.2K
Figure 10.1:
N.O.S. - Normally Open Supervised Connections
1
Dry Contact
3
Dome Connector
2
Alarm 1 or 2 only (Pin 5 or 6)
4
Ground (Pin 7)
3.
From
Configuration
, select
Alarm
>
Alarm Inputs
. For
Input
1, enter a
Name
for the
Alarm input
. In the field
Active
, select
N.O.S.
. Finally, select an
Action
. See the table
below for contact and condition details.
AUTODOME Programmed N.O.S.
Contact
Alarm Condition
Open
Normal
Closed
Alarm
Cut or break
Tamper
Configuring a Normally Closed Supervised Alarm
1.
Install a 2.2 K end-of-line resistor in the alarm circuit.
2.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
camera.
2.2K
Figure 10.2:
N.C.S. - Normally Closed Supervised Connections
1
Dry Contact
3
Dome Connector
2
Alarm 1 or 2 only (Pin 5 or 6)
4
Ground (Pin 7)
3.
From
Configuration
, select
Alarm
>
Alarm Inputs
. For
Input
1, enter a
Name
for the
Alarm input
. In the field
Active
, select
N.C.S.
. Finally, select an
Action
. See the table
below for contact and condition details.
AUTODOME Programmed N.C.S.
Contact
Alarm Condition
Open
Alarm
Closed
Normal
Short
Tamper