14
en | Preparing the bubble
AUTODOME inteox 7000i - 2MP (in-ceiling)
2021-08 | 1.4 |
Installation Manual
Bosch Security Systems
4
Preparing the bubble
The inside of the housing may contain packing material to safeguard the camera during
shipping. If so, you must remove the packing material before attaching the in-ceiling housing
to the interface box.
i
Notice!
To avoid excessive moisture saturation inside the housing, limit the amount of time that the
bubble is disconnected from the housing. Bosch recommends that the bubble be removed
from the housing for no more than five (5) minutes.
Remove the bubble from an in-ceiling housing
1.
Loosen the lockscrew (item 1 in the illustration below) in the trim ring using a P1 or
smaller Phillips screwdriver until the bubble can rotate freely.
2.
Rotate the bubble counterclockwise approximately 1/4 turn until it releases from the in-
ceiling housing. See the figure below for an illustration.
Figure 4.1:
Remove the bubble
4
Remove the foam inserts surrounding the camera module.
After you remove the bubble
4
Visually examine the inner and the external surfaces of the bubble for debris, dirt, or
residue. If you must clean the bubble, refer to the steps that follow for instructions.
Bubble Cleaning
If cleaning the bubble is required, use the following procedures and comply with all the
warnings listed below.
Cleaning the Bubble Interior
The extremely soft interior surface should not be cleaned by rubbing or dusting with a cloth.
Use clean dry compressed air, preferably from a spray can, to remove any dust from the
interior surface.
!
Warning!
Do not use alcohol-based solutions to clean the bubble. This will cause the surface to cloud
and, over time, cause stress aging, which makes the bubble brittle.