54
en | Connection
AUTODOME inteox 7000i - 2MP (pendant)
2020-07 | 1.0 |
Installation Manual (pendant)
Bosch Security Systems
Notice!
The heater in an outdoor AUTODOME unit cannot be powered via the Power-over-Et
(IEEE 802.3at, class 4) standard, unless the heater is connected to a High PoE Midspan 60W,
Single port (sold separately). See the Installation Manual of the Midspan for details.
Cable Type
CAT-5E or CAT 6 Ethernet
Maximum Distance
100 m (328 ft)
Bandwidth
10 Base-T/100 Base-TX
High PoE (required for pendants in outdoor applications that use
heaters)
Use the Bosch High PoE 60W midspan
(sold separately).
PoE+ (only for indoor models or indoor applications for pendant model
where heater is not required)
IEEE 802.3at, class 4 standard
Terminal Connector
RJ45, Female
Notice!
Consult the National Electrical Code (NEC) for cable bundling requirements and limitations.
13.4
Fiber Optic Ethernet Media Converter (Optional)
The fiber optic media converter is designed to transmit 10/100 Mbps Ethernet signals over
fiber optic cable using 10/100 Mbps Small Form-factor Pluggable (SFP) modules. The SFP
modules are available as multi-mode fiber (MMF) or single-mode fiber (SMF) models with a
single SC connector or dual-fiber with an LC connector. Refer to the VG4-SFPSCKT Fiber
Optic Media Converter Installation Guide.
Ethernet Media Converter
Data Interface
Ethernet
Data Rate
10/100 Mbps
IEEE 802.3 Compliant
Full Duplex or Half Duplex Electrical Port
Full Duplex Optical Port
Fiber Type, MMF
50/125 µm MMF. For 50/125 µm fiber, subtract 4 dB from the specified optical budget
value. Must meet or exceed fiber standard ITU-T G.651.
Fiber Type, SMF
8–10/125 µm SMF. Must meet or exceed fiber standard ITU-T G.652.
Maximum Distance
20 km (12.4 miles)
Requirement
Media converter receiver (CNFE2MC/IN) at controller end of system
Terminal Connection Duplex LC or Single SC