English–
23
Bosch eBike Systems
0 276 001 SPUen | (23.4.14)
Technical Data
Assembly
Put the battery pack down only on clean surfaces.
In
particular, avoid getting the charge socket and the con-
tacts dirty, e. g., with sand or soil.
Checking the Battery Pack Before Using
for the First Time
Check the battery pack before charging it or using it with
your eBike for the first time.
To do this, press the On/Off button
A4
to switch on the bat-
tery pack. If no LED for the charge-control indicator
A3
lights up, then the battery pack may be damaged.
When at least one of the LEDs, but not all, for the charge-
control indicator
A3
is lit, then fully charge the battery pack
before using it for the first time.
Do not attempt to charge or use a damaged battery
pack.
Please contact an authorized Bosch eBike dealer.
Charging the Battery Pack
Only use the Bosch charger provided with your eBike
or an identical original Bosch charger.
Only this char-
ger is matched to the lithium-ion battery pack used in
your eBike.
Notice:
The battery pack is supplied partially charged. To
ensure full battery pack capacity, completely charge the
battery pack in the charger before using it for the first time.
To charge the battery pack, read and follow the operating
instructions for the charger.
The battery pack can be recharged at any time on its own or
on the bike without shortening the its service life. Interrupt-
ing the charging process does not damage the battery pack.
The battery pack is equipped with a temperature control in-
dicator, which enables charging only within a temperature
range between 32 °F and 104 °F.
When the battery pack is not within the
charging temperature range, three
LEDs of the charge-control indicator
A3
flash. Disconnect the battery pack from the charger until its
temperature has adjusted.
CAUTION: Do not connect the battery pack to the
charger until it has reached the permissible charging
temperature.
Charge-control Indicator
When the battery pack is switched on, the five green LEDs
for the charge-control indicator
A3
indicate the charge con-
dition of the battery pack.
Here, each LED indicates approx. 20 % capacity. When the
battery pack is completely charged, all five LEDs light up.
The charge-control for the switched on battery pack is also
indicated on the display for the display unit. Read and fol-
low the operating instructions for the drive unit and the dis-
play unit.
When the capacity of the battery pack is below 5 %, all LEDs
for the charge-control indicator
A3
on the battery pack turn
off; however, the display unit does provide an additional in-
dicator function.
Lithium-ion battery pack
PowerPack 400
Article number
– Standard battery pack
– Rack-type battery pack
0 275 007 524
0 275 007 525
Rated voltage
V=
36
Rated capacity
Ah
11
Energy
Wh
400
Operating temperature
°F
+23...+104
Storage temperature
°F
+14...+140
Permitted charging tempera-
ture range
°F
+32...+104
Weight, appox.
lb
5.5/5.7
Degree of protection
IP 54 (dust and splash
water protected)