139
Installation
www.bora.com
EN
Connection
Fuse
protection
Minimum
cross-section
Three-phase connection 3 x 16 A
2.5 mm
2
Two-phase connection 2 x 16 A
2.5 mm
2
One-phase connection 1 x 32 A
4 mm
2
Tab. 10.2
Fuse protection and minimum
cross-section
4
N2
5
N1
L1
220
-
240 V
~
L2
2
3
L3
1
220
-
240 V
~
220
-
240 V
~
PE
Fig. 10.38
Connection diagram – three-phase
connection
4
N2
5
N1
L1
220
-
240 V
~
L2
2
3
L3
1
220
-
240 V
~
PE
Fig. 10.39
Connection diagram – two-phase
connection
4
N2
5
N1
L1
L2
2
3
L3
1
220
-
240 V
~
PE
Fig. 10.40
Connection diagram – one-phase
connection
2
1
Fig. 10.41
Electrical connections of the cooktop
[1]
Power supply cover
[2]
Mounting eyes
X
Connect the power supply cable to the power
supply of the appliance in accordance with the
relevant connection diagram.
X
For a one-phase or two-phase connection,
connect the relevant contacts using the bridge
provided (in scope of delivery).
X
Secure the connection cable with the strain relief
clamp (in scope of delivery).
X
Close the power supply housing with the power
supply cover [1] (in scope of delivery).
X
Lay the connection cable along the mounting
eyes [2] with the help of the cable ties (in scope
of delivery).
X
Ensure that the cable is not trapped or damaged
and is not able to come into contact with any hot
areas on the cooktop.
X
Attach the bottom of the suction chamber with
the 5 suction chamber locks.
X
Check that installation has been carried out
correctly.