129
Installation
www.bora.com
EN
O
A minimum clearance of 120 mm between the
back panel of the unit and an adjacent kitchen
unit or room wall must be observed for the air
duct.
O
No false floor is necessary below the cooktop.
If cable protection (false floor) is planned, the
following must be taken into account:
O
It must be fitted in such a way that it can be
removed from below for maintenance work.
O
To ensure sufficient cooktop ventilation, a
minimum distance of 15 mm to the bottom
edge of the cooktop is to be observed.
O
The drawers and/or shelves in the floor unit must
be removable.
O
For correct installation, the drawers of the
floor unit must be shortened depending on the
installation situation.
10.6.2 Installation dimensions
min. 600
min. 50
199
120
5
40
(min. 424)
max. 430
60
min. 455
min. 329
min.
100
97
310
PUXA Abluft (Insel):
PUXU (Zeile 600):
PUXA Abluft (Zeile 600):
BORA X Pure
B O R A L Ü F T U N G S F I B E L
XX
min. 600
min. 50
199
495 - 575
0 - 80
min. 25
525
(min. 495)
125
700
(min. 600)
min. 50
199
120
6
40
530
(min. 314)
min. 455
50
min. 279
min.
100
97
60
310
PUXU mit zusätzlichem Teleskopauszug PULBTA (Insel):
min. 675
min. 50
199
600 - 680
105 - 185
min. 25
min. 600
125
Fig. 10.9
Installation dimensions for exhaust air,
worktop depth 600 mm
10
10 - 40
Fig. 10.8
Overlay dimensions for surface mounting
10.6 Installing the appliance in
exhaust air mode (PURSA)
i
National and regional laws and regulations
must be observed with regard to the exhaust
duct design.
i
A sufficient air supply must be ensured
i
The exhaust air must be directed to the
outside by appropriate exhaust air ducts.
i
The minimum cross-section of the air ducts
must be 176 cm
2
, which equates to a round
pipe with a diameter of 150 mm or the BORA
Ecotube duct system.
i
As a general rule, with the built-in fan, a length
of duct of up to 6 metres with six 90° bends,
8 metres with four 90° bends or 10 metres
with two 90° bends can be installed.
i
Not compatible with BORA Universal fans.
i
Planning instructions for the installation of
the exhaust air ducts are provided in the
BORA ventilation handbook.
10.6.1 Preparing kitchen units for the
exhaust air model
O
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.
O
In the case of thin worktops, there must be a
sufficiently rigid support plate on the unit.
O
The back panel of the floor unit must be adapted
for the exhaust air duct.