background image

EN

25

Operation

www.bora.com

X

X

Use the control wheel [2] to open the cooktop 

extractor’s cover flap [1]. Depending on the direction 

in which the cover flap has been inserted, it is opened 

by turning the control wheel to the left or the right.

Switching on the cooktop extractor

Abb. 7.2 Switching on the cooktop extractor

X

X

Press in the control knob and turn it to level 1 to 

switch on the cooktop extractor.

Q

Q

The indicator light comes on.

Switching off the cooktop extractor

Abb. 7.3 Switching off the cooktop extractor

X

X

Press in the control knob and turn it to level x. 

X

X

Next, turn it back to level 0. 

Q

Q

The control knob locks into place and the cooktop  

extractor switches off.

Q

Q

The indicator light switches off.

7  Operation

X

X

Observe all safety and warning information during  

operation (see the Safety section).

INFO 

The cooktop extractor must only be operated 

with BORA cooktops.

INFO 

The cooktop extractor only works if the cover 

flap is open.

INFO 

 

The cooktop extractor should only be operated 

with the stainless steel grease filter, the  

rotating mechanism and the cover flap installed.

7.1  Operating the cooktop extractor

Recommendations for efficient vapour extraction

X

X

Always use a lid on pots that are particularly high. This 

ensures effective vapour extraction. It also reduces 

power consumption.

X

X

Only operate the cooktop extractor at the minimum 

power level required for effective vapour extraction. 

This enables you to improve the performance of the 

odour filters in recirculation mode.

X

X

Only operate the hob at the minimum power level 

required for cooking. This reduces the cooking 

vapours and the power consumption.

X

X

Avoid strong drafts.

7.1.1  Opening the cover flap

1

2

Abb. 7.1 Opening the cover flap

[1] 

Cover flap

[2] 

Control wheel

[3] 

Indicator light

Summary of Contents for PL540E

Page 1: ...EN PL540EUMEN 000 www bora com Operating and installation instructions PL540E Cooktop extractor M8800359 000...

Page 2: ...heimer Str 32 83064 Raubling Germany Contact T 49 0 8035 907 240 F 49 0 8035 907 249 info bora com www bora com The distribution and duplication of this document as well as the use and disclosure of i...

Page 3: ...fitting on the left 18 6 5 3 Preparing for installation standard set up 19 6 5 4 Installation standard set up 20 6 6 Establishing the power connection and communication 21 6 7 Connecting external swit...

Page 4: ...label Directive 2011 65 EC RoHS Directive 1 General Target group These operating and assembly instructions are intended for the following target groups Target group Requirements Users The Device may...

Page 5: ...th symbols and signal words Safety and warning instructions are structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Results of non compliance XMeasures to minimise risk...

Page 6: ...while doing so XDo not use a steam cleaner for cleaning Steam can cause a short circuit on live parts and thus lead to property damage see the Cleaning chapter 2 Safety 2 1 General safety precautions...

Page 7: ...miliar with and comply with common national regulations and supplementary regulations of the local utility companies XDo not place any hot cookware in the area of the control panel so as not to damage...

Page 8: ...ock XSafely disconnect the device from the mains using miniature or automatic circuit breakers fuses or contactors XUse a suitable measuring device to ensure that the device is de energised Work on el...

Page 9: ...ersons or damage to device Modifications attachment parts or conversions to device can impair safety XOnly use original spare parts when carrying out repairs 2 6 Use as intended The device is solely i...

Page 10: ...umption 700 W Dimensions 110 x 540 x 167 mm Control box dimensions width x depth x height 96 x 85 x 76 mm Weight incl accessories packaging 5 kg Cooktop extractor Power levels 1 9 Tab 3 1 Technical da...

Page 11: ...maximum Qmax 626 m h 61591 Sound power level Level 1 minimum 44 dB A 60704 2 13 Level 9 maximum 67 dB A 60704 2 13 Sound pressure level additional details Level 1 minimum 32 dB A Level 9 maximum 54 dB...

Page 12: ...recircu lating air version Exhaust mode The air extracted from the cooktop is cleaned by the stainless steel grease filter and released outside through a duct system The exhaust air must not be expell...

Page 13: ...for the signal input from external switch devices e g window contact switch Q Q The Home Out contact can be used to control external installations 5 3 6 Safety shut down The cooktop extractor switche...

Page 14: ...l safety and warning information see the Safety section INFO The device must not be installed above cooling devices dishwashers stoves ovens washing machines or dryers INFO The contact surfaces of the...

Page 15: ...out dimensions X X Adhere the supplied nameplate adhesive label to the back of your operating and installation instructions 6 4 Cut out dimensions Preparing the worktop X X Create the worktop cut out...

Page 16: ...between the cooktops as well as between the cooktops and the cooktop extractor INFO Cable protection false floor should be mounted below the appliances This needs to be removable for maintenance work...

Page 17: ...ixing nut 5 to the mounting bracket and tighten the fixing nut with max 10 Nm Abb 6 12 Tighten the fixing nut 6 5 1 Installing the control box behind the floor unit s fixed front panel 1 2 3 4 6 5 Abb...

Page 18: ...l knob 6 X X Use the fixing screws provided to screw the control box onto the fixed front panel in a horizontal position from the inside This prevents the control box from twisting around Adjust the c...

Page 19: ...ation X X Now adjust the ducting parts to the height of the worktop X X Saw out the necessary cut outs for the ducting in the rear panel of the floor unit X X Depending on the installation situation a...

Page 20: ...e ducting sections with an air tight join Q Q You can also optimally adhere together the connections between the ducting sections and the plinth fan with UDB25 sealing tape INFO Position the plinth fa...

Page 21: ...ble with microfuse Q Q For the ducting only use stable duct elements with smooth pipe interiors Do not use flexible or fabric tubes Q Q The exhaust air must be directed outside or to the recirculation...

Page 22: ...ntact switches If the switch is open the cooktop extractor is out of operation X X Ensure that the universal control unit is disconnected from the power supply Preparing the universal control unit X X...

Page 23: ...of 9 mm on the stripped wire end 1 Q Q Please adhere to the maximum stripping length of 26 mm on the insulated wire 2 1 2 4 3 Abb 6 28 Open the universal control unit s cover 1 Cover 2 Electronic uni...

Page 24: ...g the external switch device Depending on the type of switch device connect the connection cables to either the Home In or the Home Out connection clamp X X Adhere to the connection diagram when conne...

Page 25: ...operation see the Safety section INFO The cooktop extractor must only be operated with BORA cooktops INFO The cooktop extractor only works if the cover flap is open INFO The cooktop extractor should o...

Page 26: ...ted charcoal filter has expired with recirculation only and the stainless steel grease filter needs to be thoroughly cleaned The filter service display is shown every time the cooktop extractor is swi...

Page 27: ...ng mechanism 8 Cleaning and Maintenance X X Observe all safety and warning information see the Safety section INFO Clean the stainless steel surfaces in the polishing direction only Q Q Regular cleani...

Page 28: ...eel grease filter absorbs the greasy particles from cooking vapours Q Q If it is no longer possible to clean the stainless steel grease filter completely it must be replaced 8 2 3 Installing the cover...

Page 29: ...The service life can be found in the operating instructions for the relevant activated charcoal filter INFO You can obtain activated charcoal filters from your specialist supplier or by contacting BO...

Page 30: ...is switched off The Home In contact is broken When using a window contact switch safety device the window must be open when the fan is operating The safety device is defective Call BORA After Sales Se...

Page 31: ...environmentally friendly way Disposal of transport packaging INFO The packaging protects the device against transport damages The packaging is made of materials that are environmentally friendly and e...

Page 32: ...7 X X In the case of faults you cannot fix yourself contact your BORA specialist supplier or BORA After Sales Service The After Sales Service will require the type designation and the serial number of...

Page 33: ...EN 33 Notes www bora com 12 Notes...

Page 34: ...EN 34 Notes www bora com...

Page 35: ......

Page 36: ...ndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 6225...

Reviews: