EN
24
Installation
www.bora.com
1
2
Abb. 6.32 Home-Out contacts with strain relief
[1]
Strain relief clamp
[2]
Snap-out element for cable feed
X
X
Check the correct installation, as well as the firm
positioning of the connection cables.
X
X
Close the cover on the universal control unit.
X
X
Make sure that the cable is not damaged.
X
X
Switch on the main switch/automatic circuit breaker.
Establishing the power connection
X
X
Connect the power supply cable for the universal
control unit to the power supply.
X
X
Put the cooktop extractor into operation
(see the Operation section).
X
X
Check all the functions are working correctly.
6.8 Handover to user
Once installation is complete:
X
X
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and
handling to the user.
X
X
Provide the user with the accessories and operating
and installation instructions to be kept in a safe place.
Installing the external switch device
Depending on the type of switch device, connect the
connection cables to either the Home-In or the Home-Out
connection clamp.
X
X
Adhere to the connection diagram when connecting
Home-In and Home-Out.
Home
In
Home
Out
X 7.1
X 7.2
X 6.1 X 6.2
Abb. 6.31 Connection diagram for the external switch contacts
X
X
Connect the cable for the relevant contact to the
switch contact clamp [4] in accordance with the
relevant connection diagram (see fig. Connection
diagram for the external switch contacts).
Q
Q
In order to connect the Home-In interface, the
installed bridge must be removed.
INFO
The Home-In contact must be bridged if this is
not used (bridged on delivery).
Q
Q
For connections to the Home-In connection clamp, no
ferrules may be used.
X
X
Clamp the connection cable in the strain relief clamp
[4] in accordance with the wire cross section used.
INFO
If external switching devices are connected
both to the Home-In and Home-Out interfaces,
both cables should be secured with the strain
relief claim [4].
X
X
Remove the relevant snap-out element [2] in the
plastic housing of the universal control unit.
Summary of Contents for PL540E