![bora PL540E Operating And Installation Instructions Download Page 23](http://html1.mh-extra.com/html/bora/pl540e/pl540e_operating-and-installation-instructions_2788201023.webp)
EN
23
Installation
www.bora.com
X
X
Use the order code UFH (universal filter sleeve) to
order the filter sleeve from your specialist supplier or
contact BORA via the website at www.bora.com.
Abb. 6.29 Wrap the connection cable round the ferrite sleeve
three times
X
X
Wrap the connection cable around the ferrite sleeve
three times to create the desired filter performance.
X
X
Ensure that the cable end protrudes at least 120 mm
from the sleeve.
X
X
Prepare the connection cable in accordance with the
prescribed stripping lengths.
6
5
3
2
1
4
9
UFH
35
120
20
Abb. 6.30 Stripping lengths and assembly position of the
connection cable in the universal control unit
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
[5]
Cable feed snap-out element
[6]
Universal ferrite sleeve (UFH)
Q
Q
Please adhere to the maximum stripping length of
9 mm on the stripped wire end [1].
Q
Q
Please adhere to the maximum stripping length of
26 mm on the insulated wire [2].
1
2
4
3
Abb. 6.28 Open the universal control unit’s cover
[1]
Cover
[2]
Electronic unit
[3]
Base unit
[4]
Switch contact clamp
INFO
The electronic unit [2] can contain residual
charge. You must therefore be careful not to
touch the exposed contacts on the electronic
unit!
Preparing connection cables for external
switching equipment
Use the following types of connection cables from the
following manufacturers to connect external switching
equipment.
Contact
Connection cable
Home-In
H03VV-F 2x0.5mm²
Home-Out
H03VVH2-F 2x0.75mm²
Tab. 6.5: Connection cable
INFO
The connection cable is only intended for
indoor use in buildings, private homes,
kitchens or offices!
INFO
The overall length of the connection cable for
external switching equipment must not exceed
10 m!
For reasons of electromagnetic compatibility, all connection
cables from external switch devices must be filtered with a
ferrite sleeve. This is not included in the scope of delivery.