EN
17
Installation
www.bora.com
Fixed
front
panel
thickness
[mm]
Total thick-
ness of
adjustment
plates
[mm]
Adjustment plates [quantity]
10 mm 5 mm 3 mm 2 mm
34
2
-
-
-
1
33
3
-
-
1
-
32
4
-
-
-
2
31
5
-
-
1
1
30
6
-
-
2
-
29
7
-
1
-
1
28
8
-
1
1
-
27
9
-
1
-
2
26
10
1
-
-
-
25
11
-
1
2
-
24
12
1
-
-
1
23
13
1
-
1
-
22
14
1
-
-
2
21
15
1
1
-
-
20
16
1
-
2
-
19
17
1
1
-
1
18
18
1
1
1
-
17
19
1
1
-
2
16
20
1
1
1
1
15
21
1
1
2
-
14
22
1
1
1
2
13
23
1
1
2
1
Tab. 6.3: Adjustment plate overview
Secure the control box
X
X
Position the power level sleeve [4] on the fixed front
panel [3].
X
X
Position the control box [1] with the attached
adjustment plates [2] from the back into the bore hole
in the fixed front panel.
X
X
Screw on the fixing nut [5] to the mounting bracket
and tighten the fixing nut with max. 10 Nm.
Abb. 6.12 Tighten the fixing nut
6.5.1 Installing the control box behind the
floor unit’s fixed front panel
1
2
3
4
6
5
Abb. 6.10 Control box structure
[1]
Control box
[2]
Adjustment plates
[3]
Fixed front panel (not included in the scope of delivery)
[4]
Power level sleeve
[5]
Fixing nut
[6]
Control knob
X
X
Draw the bore hole accordingly with the aid of the
drilling template provided.
1
2
5
>105
37
Ø6
Ø30
Abb. 6.11 Drilling template
[1]
Worktop
[2]
Fixed front panel
X
X
Pre-drill the bore hole to prevent tearing out the panel.
Determining the number of adjustment plates
Q
Q
The total dimensions of the adjustment plates [2] and
the fixed front panel [3] should be 36 mm.
Q
Q
The total dimensions of 36 mm must be adhered to in
order to ensure that the control box [1] functions
smoothly.
Summary of Contents for PL540E