9 Troubleshooting
X
X
Observe all safety and warning information (see the Safety section).
Operating situation
Cause
Remedy
The cooktop extractor cannot be
switched on.
The fuse or automatic circuit breaker
of the electrical wiring system in the
apartment and/or house is defective.
Replace the fuse.
Switch the automatic circuit breaker
back on.
The fuse or the automatic circuit
breaker trips several times.
Call BORA After Sales Service.
The power supply is disconnected.
Have a specialist electrician inspect
the power supply.
The microfuse in the universal control
unit‘s cooling device plug is defective.
Replace the fuse
(type: T3, 15 A/250 V).
The indicator light flashes rapidly for
5 seconds and the fan is switched off.
The Home-In contact is broken.
When using a window contact switch
(safety device), the window must be
open when the fan is operating.
The safety device is defective.
Call BORA After Sales Service.
Odours form when operating the cook-
top extractor.
This is normal on brand-new
appliances.
Odours stop forming after a few
operating hours.
The extraction performance of the
cooktop extractor has decreased.
The stainless steel grease filter is
heavily soiled.
Clean or replace the stainless steel
grease filter.
The activated charcoal filter is heavily
soiled (recirculation only).
Replace the activated charcoal filter.
There is an object in the air guiding
housing (e.g. cleaning cloth).
Remove the object.
The fan is defective or a duct
connection has become loose.
Call BORA After Sales Service.
Tab. 9.1: Resolving a fault
X
X
In all other instances, call BORA After Sales Service (see the Warranty, After Sales Service and spare parts section).