10
6-G
:
Anti reset wind up setting
Control the overshooting
Default
:18%
Setting range
:0
~
100%
Ⅰ
:
At the operation modee, press
for 3 seconds while pressing
△
key.
is
indicated at PV display.
Ⅱ
:
Push
4 times , and
is indicated at PV display.
Ⅲ
:
Enter the desired value by
△
key or
▽
key at SV display.
Ⅳ
:
3 times to return to the operation mode.
We recommend that you should keep the default. The lower value than the default can restrain
overshooting, but there might be possible not to recover to the set temperature.
6-H
:
Auto Power Down / Auto Power Off
In order to prevent soldering iron tips from Deterioration and Oxidization, the tip
temperature is lowered ( Power Down), and the supplying electric power to the heater is
stopped (Power Off) automatically when the tip temperature does not change for a certain
period of time (User- settable). This function is not only effective for saving energy, but
also for safety.
Operation mode
⇒
Auto Tuning
⇒
Anti reset wind up
⇒
Operation mode
Operation mode
Power Down
Power Off