6
②
-2
How to set the sensor type
Ⅰ
:
At the operation mode, press
key approx. 3 seconds while pressing
▽
key.
is indicated at PV display.
Ⅱ
:
Enter suitable sensor type by
△
key or
▽
key, then push
mode.
Operation modee
⇒
Input screen
⇒
Select sensor type
Operation modee
⇒
TYPE K
(
℃
)
⇒
TYPE J
(
℃
)
③
Set the set temperature
Default
:350
℃
Setting range
:0
~
500
℃
Default
:200
℃
※
when
「
BNJT7
」
type iron tip equipped.
Ⅰ
:
At the operation mode, press key once, and is indicated at PV display.
Ⅱ
:
Enter the desired temperature by
△
key or
▽
key.
Ⅲ
:
Press key once to return to the operation mode.
Operation modee
⇒
Setting temp.
⇒
Operation mode
④
Temperature compensation
Default
:0
℃
Setting range
:-100
.
0
℃
~
100
.
0
℃
Ⅰ
:
At the operation mode, press
seconds while pressing
▽
key.
is indicated at PV display.
Ⅱ
:
Press key 3 times, and
is indicated at PV display.
Ⅲ
:
Enter the desired value by
△
key or
▽
key at SV display.
Ⅳ
:
After entering the value, push key 4 times to return to the operation mode.
Operation mode
Input screen
Compensation screen
Operation mode
⇒
⇒
⇒
How to calculate the compensation value with a standard thermometer.
e.g.
:
Thermometer value:
「
350
℃
」
Controller value
:
「
355
℃
」
Compensation value is
「-
5
」
Compensation value
=
Thermometer value
-
Controller value
⇒
「
350
」
-
「
355
」=「-
5
」