12/20
Quick Start Guide ACT
95
GB
8.3
Sizes 3 and 4 ACT2XX (4.0…9.2 kW, 230 V)
Type
ACT2XX
-18
-19
-21
-22
Size
3
4
Output, motor side
Recommended motor shaft power
P
kW
4.0 5.5
4)
7.5
4)
9.2
4)
Output current
I
A
18.0 22.0 32.0 35.0
I Longt overload (60 s)
I
A
26.3 30.3 44.5 51.5
I Shortt overload (1 s)
I
A
33.0 33.0 64.0 64.0
Output, braking resistor
Min. braking resistance
R
Ω
24
24
12
12
Recommended braking resistor (U
dBC
=
385 V)
R
Ω
30
24
16
12
Input, mains side
Mains current
3)
3ph
1ph/N/PE; 2ph
I
A
18
28
2)
20
1)
-
4)
28.2
1)
-
4)
35.6
1)
-
4)
Mains voltage
U
V
184 … 264
Fuse 3ph
1ph/N; 2ph
I
A
25
35
25
-
4)
35
-
4)
50
-
4)
Mechanical
Dimensions
HxWxD mm 250x100x200 250x125x200
Weight approx.
m
kg
3.0
3.7
Connection terminals
A
mm
2
0.2 … 6
0.2 … 16
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
P
W
200 225 310 420
Output current
(Maximum current in continuous operation)
Frequency inverter
nominal power
Switching frequency
2 kHz
4 kHz
8 kHz
16 kHz
4.0 kW
18.0 A
2)
18.0 A
2)
18.0 A
2)
12.2 A
5.5 kW
4)
23.0 A
1)
22.7 A
1). 5)
22.0 A
1) 5)
15.0 A
5)
7.5 kW
4)
32.0 A
1)
32.0 A
1)
32.0 A
1)
21.8 A
9.2 kW
4)
40.0 A
1)
38.3 A
1) 5)
35.0 A
1) 5)
23.8 A
5)
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance ≥ 1% (see chapter „Electrical
installation“)
4)
Three-phase connection permissible only.
5)
Reduction of switching frequency in thermal limit range
Summary of Contents for ACTIVE ACT2 Series
Page 1: ...Quick Start Guide 132 kW...
Page 2: ......
Page 3: ......
Page 4: ......
Page 13: ...12 20 Quick Start Guide ACT 11 I Grandezza 5 c c1 a a1 a2 x b b1 x x 100 mm...
Page 15: ...12 20 Quick Start Guide ACT 13 I Grandezza 6 a a1 a2 x x 100 mm b b1 x c c1...
Page 62: ...60 Quick Start Guide ACT 12 20 GB Size 5 c c1 a a1 a2 x b b1 x x 100 mm...
Page 64: ...62 Quick Start Guide ACT 12 20 GB Size 6 a a1 a2 x x 100 mm b b1 x c c1...
Page 112: ...110 Quick Start Guide ACT 12 20 D Baugr e 5 c c1 a a1 a2 x b b1 x x 100 mm...
Page 114: ...112 Quick Start Guide ACT 12 20 D Baugr e 6 a a1 a2 x x 100 mm b b1 x c c1...
Page 161: ...12 20 Quick Start Guide ACT 159 F Taille constructive 5 c c1 a a1 a2 x b b1 x x 100 mm...
Page 163: ...12 20 Quick Start Guide ACT 161 F Taille constructive 6 a a1 a2 x x 100 mm b b1 x c c1...
Page 212: ...210 Quick Start Guide ACT 12 20 E Tama o 5 c c1 a a1 a2 x b b1 x x 100 mm...
Page 214: ...212 Quick Start Guide ACT 12 20 E Tama o 6 a a1 a2 x x 100 mm b b1 x c c1...
Page 255: ......
Page 256: ......
Page 257: ......
Page 258: ...COD VEC 370 R4...