BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Page 45
Commissioning
5.1
Commissioning the compressor
Checking the leak
tightness of the com-
pressed air pipes
1. Close the mains disconnecting device.
2. Switch the compressor on and check the leak tightness of the compressed
air outlet.
3. Switch off the compressor.
4. If required: have leaks repaired by experienced skilled personnel.
Record the test results.
Opening the shut-off
valves
Open the ball valve on the compressor outlet.
Conducting a test run
1. Close the mains disconnecting device.
2. Switch on the compressor using the ON button on the compressor control.
Æ
The compressor starts.
Æ
The compressor switches off automatically once the pre-set switch-off
pressure has been reached.
3. Check the net pressure on the control display.
4. If required, adjust the operating pressure (pressure setpoint).
Æ
The compressor is ready for operation.
Æ
For the control function see the control display.
5. Switch off the compressor after a several-hour test run at maximum oper-
ating load.
Record the test results.
WARNING
Risk of injury due to overpressure!
In the event of damage, malfunctioning or incorrect use, fluids under high
pressure can escape from pipes or individual components and cause severe
injuries.
Î
Any work on the compressed air system must only be carried out by duly
authorised and experienced personnel.
Î
Wear personal protective equipment, such as protective clothing and
protective goggles.
Î
The leak tightness of the compressed air outlet connection must be
checked immediately after switching on the machine.
Î
Make sure to maintain a safe distance during the inspection.
CAUTION
Risk of injury due to moving parts or sharp edges!
Î
Open the mains disconnecting device and secure against accidental
switching on again using a padlock.