BOGE Operating instructions for scroll compressors, series EO 6...EO 22 D
Page 33
Installation
4.2
Installing the compressor
4.2 Installing the compressor
Specifications for the
compressor room
Installation surface
The compressor can be installed on a level industrial floor with no foundations.
No special fastening elements are required.
Sound protection
Only install compressors in workrooms if the sound pressure level of their
measuring surfaces does not exceed 85 dB (A).
Admissible ambient conditions
–
Installation altitude 0 to 1000 MSL
–
Closed room, frost-free, dry
–
Ambient con5°C to +40°C
–
Relative humidity 0% to 60%
ATTENTION
Danger of property damage!
Î
There should be no external vibrations affecting the compressor site.
CAUTION
Danger due to noise!
A sound pressure level exceeding 80 dB (A) can cause permanent hearing
defects in persons who always work in the vicinity of the compressor.
Î
These persons must wear hearing protection while working near the com-
pressor.
ATTENTION
Danger of property damage!
Non-observance of the admissible ambient temperatures may lead to the
following problems:
–
The compressor switches off when the maximum permitted compressed
air outlet temperature is exceeded.
–
Pipes and valves may freeze up at lower temperatures.
Measures to be taken to ensure that admissible ambient temperatures
are maintained:
Î
Avoid having any heat-radiating pipelines or units in the vicinity of the
compressor or insulate them well.
Î
Never install the compressor in the cooling air flow of other machinery.
Î
Provide the supply air inlets with adjustable louvres to ensure that the
temperature does not fall below the minimum temperature in winter.