BOGE Operating instructions for C 15 series screw compressors
Page 9
General
1.2
Introduction
Symbols on the outside cladding, part 1
Before working at the compressor:
– disconnect all current-carrying parts!
– check if all parts are actually voltage-free!
– secure the compressor against switching-on!
– reduce the pressure in all areas!
If you neglect these rules, your health will be endangered!
Before putting into service:
– read the instructions
– check electric connections
– check oil-level (not for oil-free)
– if applicable, remove the transportation safety
device
– check the direction of rotation of compressor
– operate only with a belt protective grating
or a sound protection bonnet.
– do not close the cooling air inlets and outlets
during operation!
Regular maintenance:
Observe the operating instructions!
– check suction filter
monthly
, if necessary clean
or replace it
– check cooler for dirt, if necessary clean it
– check oil-level weekly (not for oil-free)
– drain condensation water from pressure tank
at least once a week
– check operativeness of automatic steam trap