The Easy system includes a test mode that allows verification of the ventilation and fire
management system. To activate the test mode, pull the control panel slightly towards you, and
press the red button on the right side of the control panel for 5 seconds.
Once the test mode is activated, the ventilation and light management LEDs will flash.
Pressing this red button again briefly will allow you to return to the normal operating mode.
Ventilation test
In test mode, depending on the position of the cursor, the operation must be as follows:
- Cursor on the left, on minimum position: fans OFF when the door is open, fans on maximum
speed when the door is closed;
- Cursor on the right: fans ON and speed depending on the cursor position.
(!) Never leave the board in test mode while the appliance is in operation.
Air box engine test
The main board can also detect possible blocking of the air box mobile air flap. If more than one
blocking is detected, the fire management display led will display red. Here are the different
possible causes of a blocking of the mechanism:
- Motor and mobile air flap out of alignment;
- Object trapped between the flap and the heating element;
- Heavy soiling of the flap.
In test mode, depending on the position of the cursor, the mobile air flap swings between its
minimum and maximum position. This test allows detecting a possible motor blocking.
(!) Never leave the board in test mode while the appliance is in operation.
If the motor blocks before reaching its closed position (cursor positioned on the left), it is most
likely a misalignment problem between the motor shaft and the mobile air flap.
The motor and the flap can only be dismantled by technicians trained by Bodart & Gonay, as
these interventions require a thorough knowledge of the system.
Other failures
The following problems are also detected
- Communication problem with the control panel;
- Problem with the temperature sensor (thermocouple).
1.11.
First fire.
The first fire is important, and enables: