13
(!) Do not forget the minimum cross-sections of the decompression air flows.
Once the cladding has been completed, replace all the internal parts of the appliance, the
frame, the side covers and the door.
1.10.
Easy system.
This stove is equipped with the "Easy" system, which ensures control of ventilation and
combustion, with the aim of making the appliance easier to use, increasing its performance
(efficiency) and reducing its emissions.
This system, patented by Bodart & Gonay, represents a major innovation in the field of wood
heating appliances.
Description of the elements
The system is composed of the following elements:
- A control panel integrated into the removable wicket door;
- The main electronic board;
- Two fans;
- A motor unit to control the air flap;
- A mobile air distribution flap;
- A temperature sensor (thermocouple type);
- 3 cables;
- An external 24VDC power supply.
Control panel
The control panel enables the user to set up the appliance. It also allows the technician to carry
out functional tests of the various components of the system.
It consists of two sets:
- On the left, the ventilation control;
- On the right, the fire regulation.
The various possible settings are explained in the chapter "Operation: Easy System".
At the back of the control panel, a block of 4 switches (DIP switch) allows configuring the Easy
system according to the type of device. See below.
Main electronic board
This board, located on the right side of the fireplace, is equipped with two buttons and
connectors:
- Door switch;