34
FIRE IS TOO
INTENSE
16. UNCONTROLLED AIR SUPPLY
- CHECK THE STOVE DOOR AND ASH PAN FOR
TIGHTNESS
17. WOOD USED IS OF A TOO SMALL
CROSS-SECTION
- USE WOOD WITH A CROSS-SECTION OF ABOUT 12
TO 15 CM
18. MALFUNCTION OF THE AIR BOX
- CONTROL THE MOVEMENT OF THE MOBILE AIR
FLAP
THE GLASS PANEL
BLACKENS
CHECK CAUSES 5
–
7
–
9
–
10
–
11 -
12
- APPLY THE APPROPRIATE CORRECTIVE ACTION
19. CLEAN GLASS BEFORE LIGHTING
- CLEAN THE GLASS CAREFULLY
20. UNCONTROLLED AIR SUPPLY
- CHECK THE DOOR FOR TIGHTNESS
IMPORTANT
BACKFLOW WHEN
OPENING THE
DOOR
CHECK CAUSES 3 - 4
- APPLY THE APPROPRIATE CORRECTIVE ACTION
21. DOOR OPENING IS TOO FAST
- OPEN THE DOOR MORE SLOWLY
22. OPENING THE DOOR
IMMEDIATELY AFTER RELOADING
- AVOID OPENING THE DOOR DURING THE
RELOADING PHASE
23. DOOR SWITCH MALFUNCTION
- CHECK THE POSITION OF THE SWITCH
- CHECK THE ELECTRICAL CONNECTIONS (BY THE
INSTALLER)
- REPLACEMENT BY THE INSTALLER
THE CONTROL
PANEL DOESN’T
LIGHT UP
24. ELECTRICAL POWER SUPPLY
- CHECK THE POWER LINE (FUSE)
- CHECK THE PRESENCE OF VOLTAGE ON THE BOARD
BY PRESSING THE TEST BUTTON
(THEN PRESS AGAIN TO EXIT TEST MODE).
- REPLACE THE POWER SUPPLY
25. IN TEST MODE, THE FANS DO
NOT RUN
- REPLACEMENT OF THE CABLE OR FANS BY THE
INSTALLER
THE RED LED LIGHT
OF THE
VENTILATION
MODE IS ON
26. CLOGGED FILTER
- CLEAN THE FILTER
27. MISSING FILTER
- PLACE A CLEAN FILTER
28. BLOCKED OR CLOGGED FAN
- DISASSEMBLE AND CHECK THE FANS
29. DEFECT FAN CABLE
- REPLACEMENT BY THE INSTALLER
30. DEFECT FAN
- REPLACEMENT BY THE INSTALLER
THE RED LED LIGHT
OF THE FIRE MODE
IS ON
31. THE MOBILE AIR FLAP IS
BLOCKED
- CHECK THAT THE FLAP IS MOBILE
THE LED BUTTON
IS RED, CONTROL
PANEL IS GREEN
32. OTHER ERROR ON MAINBOARD
- CHECK THE WIRING AND THERMOCOUPLE
VENTILATION DOES
NOT WORK
WITHOUT AN
ERROR BEING
REPORTED
33. THE THERMOCOUPLE SENSOR IS
DEFECT
- CHECK THE SENSOR
34. THE DOOR SWITCH IS BADLY
ADJUSTED
- ADJUST THE DOOR SWITCH BRACKET