17
(!) If the bracket is placed too far forward, it may damage the door switch and the electronic
board.
Setting
The electronic board of the control panel has a 4-switch box (DIP switch) which allows setting up
the board for the device in which it is installed.
For the Infire Easy range
, here are the possible configurations:
- Infire Easy 670 & 740: "0000", all switches in lower position;
- Infire Easy 810: "1000", switch 1 up, all others in lower position;
- Infire Easy 950: "0100", switch 2 up, all others in lower position;
The configuration is set up in-factory. However, should this configuration be modified:
- Modify the configuration;
- Check that the control panel is properly connected to the main board;
- Restart the main board.
There are two ways to restart the board:
- Turn off the power supply for 20 seconds and then turn it on again;
- Reset the board (see next chapter).
Reset of the main board
A long 5-second press on the led-button will restart the electronic board.
Troubleshooting
The main electronic board constantly monitors the status of the various components of the
appliance. When a malfunction is detected, the led-button of the main board lights up red and,
depending on the type of malfunction detected, red LEDs light up on the control panel.
Fan control
If the fan(s) do(es) not work as expected, the ventilation LED will turn red. Here are the different
faults detected:
- Clogging of a fan --> clean the blades;
- Mechanical problem: bearing, object stuck in the fan;
- Electrical power supply problem;
- Problem with the cables (or connectors) between the board and the fan(s).
Test mode