WEBGLIDER displays double characters
Local-echo is enabled in the terminal. Reconfigure the terminal to
disable the local echo.
WEBGLIDER connects but the connection is
then lost
1. If you are using rate adaption, check that the device you are
connecting to is configured for the same rate adaption standard
as the WEBGLIDER. The WEBGLIDER uses V.120, which will
not interoperate with V.110.
2. Check that the PPP is not enabled if calling a line without PPP.
Disable PPP by typing AT&Q0. Enable it by typing AT&Q3.
WEBGLIDER will not auto-answer on RS-232
port
In AT dialing mode ‘automatic-answer’ is enabled by setting the
value of the S0 register to 1 (ATS0=1).
WEBGLIDER very slow or re-booting
Serial cables greater than a few feet in length connected to the
WEBGLIDER and left unterminated may cause problems. These
cables should be plugged into a DTE or disconnected from the
WEBGLIDER.