3.6
Locate the iL system
WARNING
You must use suitable lifting equipment to move the iL system. It is too heavy to lift by
hand.
WARNING
Ensure that the maximum angle between paired slings used to lift the iL system is 60
o
.
Use the following procedure to locate the iL system in its operating position. The iL system must
be located on a firm, level surface.
1.
Use suitable lifting equipment attached to the lifting bolts (Figure 3-2, items 1) to move the iL
system close to its final operating position.
2.
Refer to Figure 3-5. Remove the nuts and washers (4) which secure the four transit brackets
(2) to the vibration isolators (3), then remove the transit brackets.
3.
Wheel the iL system on its castors to move it into its operating position.
4.
Adjust the levelling feet to make sure that the iL system is level and is not supported by the
castors.
5.
If required, fit restraints to prevent inadvertent movement of the iL system; you can attach
these restraints to the brackets fitted to the sides of the iL system.
3-10
iL Dry Pumping Systems
Figure 3-5 - Remove the vibration isolator transit brackets