5. Safety-Precautions and Warnings
•
This device produces dangerous electrical voltages and is used for the operation of dangerous
moving mechanical parts. For this reason, only professionally trained and qualified personnel
should be allowed to install and repair this device!
•
The operation with disconnected PE connection is not allowed.
•
Any maintenance or repair work to the device must only be carried out after the supply voltage
has been disconnected!
•
Before the first commissioning can be carried out, it should be established that the motor is
installed correctly and securely, to eliminate the possibility of uncontrolled movement of the
motor.
•
Safety regulations that are valid for the country where the device is used, have to be adhered to
where any work is carried out on the device.
•
Maintaining EMC (electromagnetic compatibility) limits is the responsibility of the manufacturer of
the machine or device. The inputs and outputs on this device are fitted with filters, to increase the
interference immunity and reduce emitted interference, making it possible to use this device in an
industrial environment.
•
The EMC of a machine or device is affected by all connected components (motor spindle, length
and type of cables, wiring, etc). Under certain conditions the use of additional filters can be
necessary to maintain the current laws.
•
For the reasons listed above, installation and connection of the device should be carried out by
qualified personnel only.
6. Connections, Interfaces and Pinouts
For embedding into PLC and controls the SFU0303 has several input and outputs.
These are realized as pluggable screw terminals and lead out at front and rear panel (depending
on case option). All contacts are separated galvanically from high voltage carrying circuits.
Operational parameters and outputs:
The
SFU-0303
covers all current important operational parameters and operating data.
Up to 6 digital outputs can be used for signalling and up to 2 analogue values can be output to
the analogue outputs (0-10V) .
Remote Control and Outputs:
6 digital inputs (24V) and 2 analogue inputs (0-10V) are available for remote control of the
SFU-0303
.
These assignments can be configured freely. By using the optional Windows PC software "
SFU-
Terminal"
the above mentioned assignments can be achieved easily, providing exceptional
flexibility with each application.
Each operating parameter can be assigned as a signal and each control signal can be allocated
the required I/O pin. In addition, the logic level (high or low active) can be individually defined.
The same assignment is also possible for the analogue measured data and control data at the
analogue I/O pin.
The standard allocations of operational parameters, their outputs, control signals and inputs, are
listed in the following tables.
Summary of Contents for SFU-0303 Series
Page 1: ...Frequency Converter SFU 0303 SSE Version Desktop Version 19 Version ...
Page 6: ...SFU 0303 M a n u a l E 6 3 Block diagram picture 1 ...
Page 44: ...SFU 0303 M a n u a l E 44 17 2 19 Version ...
Page 45: ...SFU 0303 M a n u a l E 45 17 3 Version Desktop ...
Page 46: ...SFU 0303 M a n u a l E 46 this page is left intentionally left blank ...
Page 47: ...SFU 0303 M a n u a l E 47 this page is left intentionally left blank ...