Error Description
Cause
Fixing
Incorrect connection cable or wiring
fault
> Check cable for proper Pinout.
> Verify at USB cables that it's length is not
longer than 2m
> Try to use original BMR cables, only.
In case of using RS232
> Use the USB-Interface at the PC together
with a USB-RS232 converter.
> For use with SFU 0303 a specific RS232
cable is required
In case of using a USB-RS232
converter the USB-driver is not
installed correctly.
install driver
In case of connecting the
converter with a PC or
after launching the SW
SFU-Terminal
the
Converter is not
detected and not
recognized
unsure
Restart
SFU-Terminal
Start with
push
buttons
not possible
Start button deactivated
Enable Start button by un-checking the
checkbox "Block Start Button"
An input is assigned with the function
Emergency Stop
and configured as
"Low Active".
> This is default state on delivery
> For unlocking, a signal of "HI" / +24V is
required at this input
> Deactivate this function or setup as "High
Active"
The evaluation of the temperature
sensor is activated in the spindle
characteristic, but it is not connected
or a sensor isn't implemented within
the spindle
-> in this case
Error
is indicated,
additionally
> Connect the temp sensor wires with the
SFU .
> un-check the button "Temp Sensor" in the
spindle characteristic in
SFU-Terminal
Spindle does not start
,
in spite of a valid signal
for Start
The spindle test is engaged
> Check cable and connections for proper
wiring or short circuit
> Check spindle
Summary of Contents for SFU-0303 Series
Page 1: ...Frequency Converter SFU 0303 SSE Version Desktop Version 19 Version ...
Page 6: ...SFU 0303 M a n u a l E 6 3 Block diagram picture 1 ...
Page 44: ...SFU 0303 M a n u a l E 44 17 2 19 Version ...
Page 45: ...SFU 0303 M a n u a l E 45 17 3 Version Desktop ...
Page 46: ...SFU 0303 M a n u a l E 46 this page is left intentionally left blank ...
Page 47: ...SFU 0303 M a n u a l E 47 this page is left intentionally left blank ...