SFU-0303
M a n u a l
E
- 11 -
6.2 Version SSE: Digital and Analogue Outputs X3
(
12 pin Pluggable screw terminal
)
Picture 3
Pin
Description
Direction
Function / Message / default Setting
1
RelayCommon
Common Rail Relay 1..5
2
Relay6 Normally closed Output
Feedback signal for
Power Stage Pulse Lock
state
3 Relay5
Normally
closed
Output
Excess temperature
Converter or Spindle
4 Relay4
Normally
closed
Output
Overload
5 Relay3
Normally
closed
Output
Standstill
Converter and Spindle
6 Relay2
Normally
closed
Output
Spindle Ready
7
Relay2 Normally open Output
8 Relay1
Normally
closed
Output
Converter Ready
9
Relay1 Normally open Output
10 Analog Out 1
Output
11 Analog Out 2
Output
12 Hall Sensor-Output
Output
modified signal square shape signal from encoder
The Default-settings of the functions for the outputs can be set up freely with the help of the PC-
Software SFU-Terminal.
An exception is the signal "Power Stage Pulse Lock", which is linked fix with Relay 6. According to the
switch state it will be output 0V / GND or +24V via 10k
Ω
referring to GND (X2.9) (-> 8.2 / 8.7)
+24V: Power Stage released 0V: Power Stage locked.
•
The digital outputs (Relay1...5) are galvanically separated (500V
Isolation
).
DC: 24V / 1000mA
AC: 125V / 500mA
•
Output level Speed / Hall Sensor: 0-24V (24V Level)
Summary of Contents for SFU-0303 Series
Page 1: ...Frequency Converter SFU 0303 SSE Version Desktop Version 19 Version ...
Page 6: ...SFU 0303 M a n u a l E 6 3 Block diagram picture 1 ...
Page 44: ...SFU 0303 M a n u a l E 44 17 2 19 Version ...
Page 45: ...SFU 0303 M a n u a l E 45 17 3 Version Desktop ...
Page 46: ...SFU 0303 M a n u a l E 46 this page is left intentionally left blank ...
Page 47: ...SFU 0303 M a n u a l E 47 this page is left intentionally left blank ...