6.8 Desktop Version: Mains and Spindle connection
The connection with mains network is carried out with an IEC connector
The device is equipped with a Thermo-Automatic Fuse for each prong. They can be reset after tripping
by pressing down the button
The spindle connection is realized on custom order and can be realized accordingly
Backside SFU0303-Desktop equipped with a 7pin circular spindle connection Picture 8
Spindle Connection
7pol. female Binder Series 693 or Amphenol C16-1
6
SGND Signal GND for PTC- and FP-Signal
5
W
Spindle Phase 3
4 FP
for
speedsensor
of
the
spindle
7
PE
Protective
Earth
3
V
Spindle Phase 2
2
PTC
for temperature sensor of the spindle
1
U
Spindle Phase 1
IEC Mains connection
Sicherungsau
Automatic Fuse
Spindle connection
Control wires, Mains cables and spindle cables should be installed separately.
For wiring, the use of shielded cables is recommended.
I/O Interface
Spindle Interface