G2S BPAP Series User Manual V2.1
27 / 43
14.2 Options of the Patient Menu and Corresponding
Descriptions
Option
Range
Description
Humidifier
Off / 1
~
5
There are five humidity levels available. As the numbering
increases, the humidity rises accordingly. “Off” means the
humidifier is turned off
Tube
15 mm / 22 mm Setting diameter of the tube by adjusting this option
Reslex
Off / 1
~
3
This feature enables the device to automatically reduce the
treatment pressure when the patient exhales, so as to make
the user more comfortable. The higher the numbering is, the
more pressure the device reduces. “Off” means this feature is
disabled
Ramp Time
0
~
Max Ramp
In order to increase comfort and help the patient fall asleep
easily, the pressure can increase gradually, when the Ramp
feature is enabled. The ramp time during which the initial
pressure rises to the prescribed treatment pressure can be
adjusted. As you turn
the Knob
to the nearest point,
the numbering increases or decreases by five minutes. The
screen displays a real-time countdown of the remaining ramp
time in minutes
Delay
On / Off
When the humidifier is on, this feature allows the airflow to
continue for about 15 minutes at a low pressure (about 2 hPa)
after you press
the Knob
to discontinue treatment. This
will blow off the vapor left in the humidifier to avoid any
damage to the device. When this feature is set to “Off,” which
means it is disabled, the airfolw stops delivering air instantly
after you press
the Knob
Date
2000-01-01
—
2099-12-31
Set date by adjusting this option
Time
00:00
—
23:59
Set time by adjusting this option
Brightness
High / Low
Setting screen brightness by adjusting this option
Mask Type
Full Face/
Nasal/
Pillow/
Other
There are three mask types available, Full Face (full-face
mask), Nasal (nasal mask), and Pillow (nasal pillow mask).
The patient can choose other suitable masks as well. When
selecting masks other than the above three types of masks,
the patient can identify the masks as Other
iCode
iCode/
iCode QR/
iCode QR+
iCode provides access to the patient's compliance data
during a recent time period. The iCode mode displays data in
sequences of numbers, and the iCode QR / iCode QR + mode
displays data in two-dimensional codes
Use Time
0
~
50000 h
Use Time displays how long has the device been used by the
patient. The use time can be erased
About
Model / SN/
Firmware
version /
ID / PIN
Show the relevant information about the device, this is only for
users to view, can not be modified. Model: the device model;
SN: Serial Number of the device; Firmware version: Software
version of the device; ID: Contains information such as gallery
and language; PIN: Personal identification code