Page 12

9.2 

Tube Installation

Step 1

Step 2

NOTE

: Your hand should only come in contact with the 

installation tool.

Place the switch in the Manual (MAN) position.

Use the installation tool to leverage the tubing into the pump 
head while the rotor is rotating.

Step 3

PULL

Step 4

Suction side
tube adapter

Installation Tool

Installation Tool

Discharge side
tube adapter

Tube Installation Tool

90002-278

NOTE

: Thoroughly clean the pump head and rotor. Rotor can be removed by pulling straight out. After the 

cleaning process, push the rotor back on the shaft. Refer to the drawing below for proper assembly. 

NOTE

: For the rotor direction, the word, “FRONT,” on the rotor must face forward (front of the pump).

®

FlexFlo

Ensure the pump is stopped.

With the pump stopped, press the suction side of tube 
adapter securely into the pump head.

Clip tube installation tool to discharge side of tube adapter.

NOTE

: Always keep fingers away from the rollers and rotor.

Continue to hold onto the installation tool

Allow rotor to rotate a few times. This will stretch tubing out.

After a few rotations, pull the installation tool and tubing in 
the direction of rotation.

Press the discharge side of tube adapter securely into the 
pump head.

Place the switch in the OFF position.

The suction and discharge tube adapter ends should be 
securely held in place on the pump head as illustrated in 
photo.

Secure the pump head cover to the pump head using the 
four black thumb screws (maximum torque 6-8 in. lbs.). 

Page 13

10.0  Pump Maintenance

Always wear protective clothing, face shield, safety glasses and gloves when working on or 
near your metering pump.  Additional precautions should be taken depending on solution 
being pumped. Refer to MSDS precautions from your solution supplier.

Routine Inspection and Maintenance

The pump requires minimal maintenance. However, the pump and all the accessories should be checked weekly, 
especially when pumping chemicals. Inspect all the components for signs of leaking, swelling, cracking, discolor-
ation, or corrosion. Immediately replace worn out or damaged components.

Cracking, crazing, or discoloration during the first week of operation are signs of a severe chemical attack. If this 
occurs, perform the following steps:

1.  Immediately remove the chemical from the pump. 

2.  Determine which parts are being attacked.

3.  Replace the damaged parts with parts that have been manufactured using more suitable materials. 

4.  After servicing, operate the pump to verify normal operation. 

NOTE

: The manufacturer does not assume responsibility for damage to a pump that has been caused by a 

chemical attack.

How to Clean and Lubricate the Pump

>

 

The pump will require occasional cleaning, and it will depend on the severity of service.

>

 

When changing the pump tube assembly, the pump head chamber, the roller assembly, and the pump head 

cover should be wiped of any dirt and debris. 

>

 

Clean the motor shaft with a clean towel, and then apply a small amount of grease to the shaft. This will help 

prevent the rotor from sticking to the motor shaft.

>

 

Periodically, or when necessary, grease the pump head cover bearing. Apply a small amount of grease  

(Aeroshell aviation grease #5 or equivalent).

>

 

100% silicone lubrication may be used on the roller assembly.

>

 

Periodically clean the injection fitting /check valve assembly, especially since injecting fluids, like sodium 

hypochlorite, can calcify. These lime deposits and other buildups can clog the fitting, increase back pressure, 
and interfere with the check valve operation. 

>

 

Periodically clean the suction strainer.

!

CAUTION

Allen Wrench

90008-162

®

FlexFlo

Summary of Contents for FLEXFLO A2P Series

Page 1: ...l sales blue white com techsupport blue white com URL www Blue White com SERIES A2P Operating Manual system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSeries Protected by Patents 8 41...

Page 2: ...sions 6 4 3 Installing Injection Fitting and Strainer 7 5 0 Power Connections 8 5 1 Wiring Terminal and I O Schematics 9 6 0 How to Adjust the Output 10 7 0 Tube Failure Detection TFD 10 8 0 Alarm Rel...

Page 3: ...metering pump 4 1 2 inches 11 43 cm off the ground or surface n Made out of tough Stainless Steel n Provides a stable mounting surface Stainless steel extended brackets allow the pump to be securely m...

Page 4: ...BT Rollers PVDF Roller Bearings SS Ball Bearings Motor Shaft Chrome plated steel TFD System Sensor Pins Hastelloy C 276 Power Cord 3 conductor SJTW A water resistant Tube Installation Tool GF nylon Mo...

Page 5: ...4X Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with enclosed equipment to provide a degree of protection against falling dir...

Page 6: ...rge line becomes blocked NOTE The does not require back pressure Keep the discharge pressure as FlexFlo peristaltic metering pump low as possible to maximize the tube life 4 2 Dimensions All diagrams...

Page 7: ...T Discharge Injection Fitting Check Valve Suction Tubing and Strainer Weight Ceramic Suction Tubing PVC 3 8 95 cm OD X 1 4 64 cm ID Strainer Polypropylene PVDF Spring Hastelloy C 276 PVDF O Ring TFE P...

Page 8: ...uto restart feature which will restore pump to operating state it was in when power was lost NOTE When in doubt regarding your electrical installation contact a licensed electrician Electrical connect...

Page 9: ...OT FUSE F1 N A 5 AMP 5A SLOW BLOW 20 X 5MM INPUT FVS SYSTEM FLOW VERIFICATION SENSOR FV SENSOR ONLY INPUT REMOTE START STOP DRY CONTACT C NORM CLOSED NORM OPEN COMMON Shielded cables should be used on...

Page 10: ...mical Detection To determine if the chemical used will be detected by the system remove the pump head cover and the pump tube and roller assembly Place a small amount of chemical in the bottom of the...

Page 11: ...ll cause the solution to squirt when disconnecting the tube connections Disconnect the system plumbing from the pump tube adapters Step 2 Place the switch in the OFF position Using the provided tool r...

Page 12: ...on the rotor must face forward front of the pump FlexFlo Ensure the pump is stopped With the pump stopped press the suction side of tube adapter securely into the pump head Clip tube installation tool...

Page 13: ...als 4 After servicing operate the pump to verify normal operation NOTE The manufacturer does not assume responsibility for damage to a pump that has been caused by a chemical attack How to Clean and L...

Page 14: ...THIS PAGE IS INTENTIONALLY LEFT BLANK Page 14 FlexFlo...

Page 15: ...Ibs 4 required per pump sold individually A2 SXX C 90011 237 1 1 2 Roller Assembly Complete Rotor For NEE and NGG Tubes A2 SNGG R 1 Tubing in this group are interchangeable with single roller assembl...

Page 16: ...informed and aware of the precautions to be taken when injecting various chemicals especially those considered hazardous or dangerous eye protection must be worn when working around this product or a...

Reviews: