Page 6
4.1
Mounting Location
1. Choose an area located near the chemical supply tank, chemical injection point, and electrical supply. Also,
choose an area where the pump can be easily serviced.
2. Finding a secure surface and using the provided 316SS mounting bracket, mount the pump close to the
injection point. Keep the inlet (suction) and outlet (discharge) tubing as short as possible.
NOTE
: Mounting the pump lower than the chemical container will gravity-feed chemical into it. This “flooded
suction” installation will reduce output error due to increased suction lift. A shut-off valve, pinch-clamp, or
other means to halt gravity-feed to the pump must be installed during servicing.
NOTE
: Install a back flow prevention check valve at the discharge side of the pump to prevent the system fluid
from flowing back through pump during tube replacement or during tube rupture.
NOTE
: It is recommended to have a pressure relief valve at the discharge side of the of pump to prevent
premature wear and damage to the pump tube, in the event that the discharge line becomes blocked.
NOTE
: The
does not require back pressure. Keep the discharge pressure as
®
FlexFlo peristaltic metering pump
low as possible to maximize the tube life.
4.2
Dimensions
All diagrams are strictly for guideline purposes only. Always consult an expert before
installing metering pump on specialized systems. Metering pump should be serviced by
qualified persons only.
!
Always wear protective clothing, face shield, safety glasses and gloves when working on or
near your metering pump. Additional precautions should be taken depending on solution
being pumped. Refer to MSDS precautions from your solution supplier.
Risk of chemical overdose. Be certain pump does not overdose chemical during backwash
and periods of no flow in circulation system.
CAUTION
!
CAUTION
!
CAUTION
G
H
I
J
K
Bottom
A
F
B
E
C
D
Front
Right
Inches
cm
A
B
C
D
E
10-1/4”
7-1/2”
14”
9-1/2”
11”
26
19
35.6
24.1
27.9
A2P Dimensions
F
3-3/8”
8.6
G
H
I
J
K
1-1/4”
3.2
2-1/2”
6.4
4-7/8”
12.3
7-1/4”
18.5
7-3/4”
19.7
Dim
Note:
Optional Extended Bracket add 4.5” (11.43cm) to overall
height (dimension A). See page 3 for details
4.0
Installation
Be sure that installation does not constitute a cross connection with drinking water supply.
Check your local plumbing codes.
!
CAUTION
Page 7
Proper eye and skin protection must be worn when installing and servicing pump.
!
CAUTION
This pump has been evaluated for use with water only
. Also, this pump has been
tested by NSF International for use with 12-1/2% sodium hypochlorite only.
!
CAUTION
Pipe
Tee
½” male NPT
1/4” male NPT
Discharge Injection Fitting / Check Valve
Suction Tubing and Strainer
Weight,
Ceramic
Suction Tubing, PVC
3/8" (.95 cm) OD X
1/4” (.64 cm) ID
Strainer,
Polypropylene
PVDF
Spring, Hastelloy C-276
PVDF
O-Ring, TFE/P (optional EP)
Ball, Ceramic
O-Ring, TFE/P (optional EP)
PVDF
Injection Nose
may be trimmed
(removed) when
injecting into
small pipe.
Install upward
for best results
Injection Fitting and Strainer for 1/4” (.64 cm) I.D. Connection End Models
4.3
Installing Injection Fitting and Strainer
®
FlexFlo
®
FlexFlo