Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Three power cord plug types available.
Power cord length is 6 feet (3.83 meters)
WARNING
>
Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage pump and may
result in injury. Voltage requirement is printed on pump serial label.
>
Input power: 115VAC 50/60 Hz 1.5 amp or 230/240VAC 50/60 Hz 0.7 amp.
>
Power switch located in Junction Box.
>
Use voltage your power cord is rated for.
>
Cord connected models are supplied with a ground wire conductor and a grounding type attachment plug
(power cord). To reduce risk of electric shock, be certain that power cord is connected only to a properly
grounded, grounding type receptacle.
>
Permanently connected models must be properly grounded. Be certain that a grounding conductor is
connected to terminal T11-1 located in wiring compartment.
>
Never strap control (input / output) cables and power cables together.
NOTE
: This pump has an auto-restart feature which will restore pump to operating state it was in when power was
lost.
NOTE
:
When in doubt regarding your electrical installation, contact a licensed electrician.
Electrical connections and grounding (earthing) must conform to local wiring codes. Be
certain that a grounding conductor is connected to terminal T11-1 located in wiring
compartment.
WARNING
6 in.
(152 mm)
Ø .50
(12.7 mm)
2-PLCS.
Ø .84 in.
(21.3 mm)
3-PLCS.
WIRING COMPARTMENT COVER
POWER CORD OPTIONS
Risk of electric shock - Disconnect electricity before removing wiring compartment
cover.
WARNING
Qty: 2 - .50 Inch (12.7 Mm) Liq-tight Hole Plugs (mat’l = Neoprene), Pre-installed
Qty: 3 - .875 Inch (22.2 Mm) Liq-tight Hole Plugs (mat’l = Neoprene), 2 Pre-installed
Qty: 2 - .50 Inch (12.7 Mm) Liq-tight Connectors For Pass Thru Cords (mat’l = Nylon)
Acceptable Cable Diameter .12 To .26 Inch (3.0 To 6.5 Mm), Not Installed
Qty: 3 - .875 Inch (22.2 Mm) Liq-tight Connectors For Pass Thru Cords (mat’l = Nylon)
Acceptable Cable Diameter .20 To .40 Inch (5.1 To =10.0 Mm), 1 Pre-installed W/ Power Cord Models
Qty: 2 - Metallic Liq-tight Connectors For .50 Inch Flexible Conduit (mat’l = Die Cast Zinc), Not Installed
QTY.
DESCRIPTION
Included cable and conduit connectors:
5.0
Power Connections
Page 9
5.1
Wiring Terminals and I/O Schematics
WARNING
FUNCTION
TERM
PIN #
RATING
ELECTRICAL SP.
BLOCK DIAGRAM
T1
T1
T1
1
2
3
(+) POSITIVE
SIGNAL
(-) NEGATIVE
OUTPUT:
RELAY, 3 AMP
OUTPUT:
CONTACT CLOSE
MOTOR ACTIVE
T3
1
T3
T3
2
3
Form C
3 AMP MAX AT
250 VAC,
3 AMP MAX AT
30 VOLT DC
NO VOLTAGE
SWITCH LOAD
3 AMP MAX @ 250V AC
3 AMP MAX @ 30V DC
OPEN CIRCUIT
IMPEDANCE MUST
BE GREATER THAN
50K OHM
Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.
Terminals T1 Thru T8
Plug type
16 - 24 AWG
Power Input Terminal T11
Plug type
14 - 30 AWG
T2
T2
1
2
(+) POSITIVE
(-) NEGATIVE
(-)
(+)
2 AMP MAX AT
250 VAC, 30 VDC
INPUT:
POWER
T5
1
T5
T5
2
3
GROUND
NEUTRAL
LINE (HOT)
FUSE
F1
N/A
5 AMP
5A SLOW BLOW
(20 X 5MM)
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY
INPUT:
REMOTE
START / STOP
(DRY CONTACT C.)
NORM. CLOSED
NORM. OPEN
COMMON
Shielded cables should be used on all input signal wires.
96 - 240 VAC
50/60 HZ
180W
T1
1
2
3
(-)
(+)
SIG
FVS
RED (+)
BLACK (-)
BARE
BLUE-WHITE
FVS SENSOR
T2
1
2
(-) (+)
N/C
REMOTE
DRY
CONTACT
T3
1
2
3
RELAY
OUT
N.O. COM N.C.
NO
C
NC
T4
1
2
3
MOTOR
A
CTIVE
N.O. COM N.C.
NO
C
NC
GROUND
LINE
(HOT)
POWER
1
2
3
T5
N EUTRAL
(COMMON)
AC
VOLTAGE
SWITCH LOAD
2 AMP MAX @ 250V AC
1 AMP MAX @ 30V DC
T4
1
T4
T4
2
3
NORM. CLOSED
NORM. OPEN
COMMON
115V 50/60Hz
NEMA 5/15 (USA)
max: 125V AC
230V 50/60Hz
NEMA 6/15 (USA)
max: 250V AC
240V 50/60Hz
CEE 7/VII (EU)
max: 250V AC
1
2
3
(-)
(+)
SIG
1
2
(-)
(+)
N/C
1
3
2
N.O.
COM
N.C.
1
2
3
N.O.
COM
N.C.
FUSE 5A
SLOW BLOW
(20 X 5MM)
F1
T1
T2
REMOTE DRY
CONTACT
FVS
INPUT
RELAY
OUT
MOTOR
A
CTIVE
T4
T3
OUTPUT
N.O. = Normally Open
N.C. = Normally Closed
COM = Common
N/C = Not connected
3
LINE
(HOT)
GROUND
1
2
T5
N EUTRAL
(COMMON)
POWER
U1
USB
®
FlexFlo
®
FlexFlo
Page 8