METHOD 2 - See Figure 2

If a separate, dedicated discharge is not possible as in Method 

1, the Back-Up DC Pump can be tied into the AC-operated 

pump’s discharge pipe by installing a “Y” or "T" connector. 

Two check valves will be required.

1.    Locate the Back-Up DC Pump on a solid, level surface in the 

  sump pit. Do not place the pump on a loose or sandy surface. 

  Small stones or sand may damage the pump resulting in 

  pump failure.

2.   This pump has a 1-1/2 in. NPT discharge. If a 1-1/4 in. 

  discharge pipe is desired, an adapter (sold separately, part 

  #66002-WYN1 adapter or equivalent) will be necessary.   

  Smaller diameter piping will reduce pump flow-rate and  

  performance.

3.   A check valve will be required in the discharge line of both 

  the Main AC pump and the Back-Up DC pump to prevent    

  recirculation of water into the sump pit. System will not  

  function without two check valves.

4.   Cut a 4 ft. section of 1-1/4 in. or 1-1/2 in. diameter rigid PVC 

  pipe. Cement 1-1/2 in. pipe to a threaded fitting. Cement 

  1-1/4 in. pipe into pipe coupling. Attach 1-1/4 in. pipe 

  section to the Back-Up DC Pump discharge adapter.

5.  Screw into pump discharge.
6.  Place the pump with the 4 ft. section of PVC pipe on the 

sump floor or on an elevated surface if required.

7.  Attach a rubber check valve (sold separately) to the top of 

the discharge pipe. This will allow the pump or check valve 

to be removed easily for servicing.

8.  Duplicate the discharge piping arrangement for the primary 

AC pump if the existing discharge line has to be adjusted to 

accommodate a second pump.

Figure 1 - Method 1 (Preferred Installation)

 

Do NOT strip or cross thread plastic  

 

fittings or check valves. Flex hose is NOT 

recommended. Rigid PVC or metal pipe is required for permanent installation.

9.  Glue a 45º elbow to the short pipe on the Back-Up DC 

Pump. Glue a “Y” adapter to the short pipe on the existing 

pump, as shown in illustration for Method 2.

10. Glue a short piece of PVC pipe between the 45º elbow and the 

“Y”.

The remainder of the discharge pipe installation will vary 

depending on individual circumstances. Using sound plumbing 

practices, route the discharge pipe to an exterior wall by the 

shortest distance.

METHODS 1 AND 2

Install float switch at least 10 in. -12 in. above bottom of sump 

pit so that back-up unit turns on only when the water level is 

higher than the normal “on” level for main pump. Make sure 

power wires and hose clamp ends do not interfere with float 

switch, pump inlet, or main pump operation. The back-up 

pump must not be allowed to run dry except during the 20 

second "auto-test. Incoming water can not flow directly onto 

the float switch. Failure to position properly may cause improper 

operation. Position the float switch so that it will not interfere 

with any portion of the plumbing, wiring, or sump pit. Check for 

clearance by lifting both floats.    

Figure 2 - Method 2 (Alternate Installation)

Floor Joist

Rigid  

PVC  

Pipe

Transformer

Check Valve

Check Valve

Primary Pump

Back-Up DC Pump

1-1/4 in.  

or  

1-1/2 in.  

PVC Pipe

Slope Pipe Down

Floor Joist

Rigid  

PVC  

Pipe

Transformer

Check Valve

Check Valve

Primary Pump

1-1/4 in.  

or  

1-1/2 in. 

PVC Pipe

Slope Pipe Down

Phone Jack

Phone Jack

12 Volt 

Advanced 

Notification 

System

12 Volt 

Advanced 

Notification 

System

Back-Up DC Pump

Figure 3 - 12 Volt Advanced Notification System elevated

Zip Tie

Zip Tie

Zip Tie

Zip Tie

 

Check valves MUST be installed in the 

 

discharge line of both the main AC pump and 

the back-up DC pump. Failure to install the check valves MAY allow 

water to recirculate into the sump pit. See Figures 1 and 2.

5

DF12VSM

www.blueangelpumps.com

Summary of Contents for DF12VSM

Page 1: ...es not include 12 Volt DC deep cycle battery phone jack phone line pipe and necessary fittings Float Switch Security DC Pump Requires active telephone land line service STEP 2 DISCONNECT POWER If the...

Page 2: ...Notes 2 Operating Instructions and Parts Manual www blueangelpumps com...

Page 3: ...lure to follow these instructions WILL result in bodily injury or death Electric shock hazard Disconnect power before servicing Apply a fixed lock or tag to prevent unexpected application of power Ele...

Page 4: ...low the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of the discharge pipe installation will vary depending on in...

Page 5: ...etal pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method...

Page 6: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Page 7: ...umber hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up system It wi...

Page 8: ...cond time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or 10 and then it will answer...

Page 9: ...determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an incoming call In most but not all...

Page 10: ...ber at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the System will answer on the second ring 3 rings 2 rings System answers on fifth 5th ring 3 Li...

Page 11: ...place if low or defective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem...

Page 12: ...allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This li...

Page 13: ...Interrupteur flotteur S curit Pompe c c Requiert un service de ligne terrestre t l phonique actif TAPE 2 METTRE HORS TENSION Si la source de courant n est pas visible verrouiller en position ouverte a...

Page 14: ...Remarques 14 Fr Instructions d Utilisation et Manuel de Pi ces www blueangelpumps com...

Page 15: ...que NE PAS marcher sur un sol mouill avant que le courant ne soit coup Faire appel un lectricien agr pour effectuer l entretien conform ment au Code national de l lectricit et aux codes locaux PROPOSI...

Page 16: ...ser des pratiques de plomberie s res pour acheminer le tuyau de d charge vers un mur ext rieur par le chemin le plus court R duire le nombre de coudes au maximum dans la mesure o qu ils r duisent le d...

Page 17: ...er un coude de 45 au tuyau court de la pompe de secours c c Coller un adaptateur en Y au tuyau court de la pompe existante comme indiqu sur l illustration de la m thode 2 10 Coller une section courte...

Page 18: ...de la batterie puis connecter le fil noir sur la borne n gative de la batterie L affichage devrait alors s allumer En cas de branchement incorrect une alarme se d clenche jusqu ce que le probl me soit...

Page 19: ...minuteries et toutes les erreurs sont effac es de la m moire du syst me maintenir le bouton RESET r initialisation enfonc pendant au moins 3 5 secondes 2 Appuyer sur le bouton MENU suivi de l option...

Page 20: ...RIE VOCALE EST INSTALL SUR LA M ME LIGNE T L PHONIQUE Pour annuler la s quence d appel d alarme sortant suivre les tapes suivantes TAPES SUIVRE 1 Appeler le syst me le num ro de t l phone du site de l...

Page 21: ...dant lorsqu un avis pr alable n est pas possible la compagnie de t l phone avisera le client d s que possible En outre vous serez inform de votre droit d poser une plainte aupr s de la FCC si vous le...

Page 22: ...g e 60 Batterie charg e 40 Batterie charg e 20 Batterie d charg e tat de la batterie sujet caution APPELT L PHONIQUE ALARME SONORE SIGNALDU SYST ME DE S CURIT Inverser la polarit Figure 6 Tableau des...

Page 23: ...terie faible ou d fectueuse 3 Interrupteur flotteur coinc 4 Fusible d fectueux ou grill 1 V rifier toutes les connexions 2 V rifier la batterie et la remplacer si elle est faible ou d fectueuse 3 S as...

Page 24: ...site de l alarme laisser sonner trois 3 sonneries puis raccrocher 2 Appeler le syst me une seconde fois dans les 3 minutes qui suivent le syst me r pondra au bout e deux sonneries 3 2 sonneries le sys...

Page 25: ...clusion ou la limitation des dommages accessoires ou indirects en cons quence les limitations pr c dentes peuvent ne pas s appliquer tous les cas Cette garantie limit e vous conf re des droits juridiq...

Page 26: ...dor Seguridad Bomba CC Requiere un servicio de tel fono de l nea activado PASO 2 DESCONECTE LA ENERG A Si la protecci n de desconexi n no est a la vista tr nquela en la posici n abierta y etiqu tela p...

Page 27: ...Notas 27 Sp DF12VSM www blueangelpumps com...

Page 28: ...u cable de corriente PUEDEN contener qu micos incluido plomo que son conocidos por el Estado de California como causantes de c ncer y defectos de nacimiento u otros da os reproductivos L vese las mano...

Page 29: ...n para un funcionamiento eficaz del sistema El resto de la instalaci n de la tuber a de descarga variar dependiendo de las circunstancias individuales Dirija la tuber a de descarga hacia una pared ex...

Page 30: ...segunda bomba 9 Pegue un codo de 45 al tubo corto en la bomba de respaldo de CC Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustraci n del M todo 2 10 Pegue una...

Page 31: ...tiva de la bater a La pantalla debe iluminarse en este momento Si se conecta de forma incorrecta sonar una alarma hasta que se corrija 4 Enchufe la bomba y los conectores del interruptor de flotador e...

Page 32: ...l nea telef nica est conectada y que la Home Screen pantalla de inicio no tenga mensajes de error 2 Presione el bot n MENU men seguido de la opci n Phone Setup configuraci n del tel fono 3 Despl cese...

Page 33: ...NTESTADORA AUTOM TICA CORREO DE VOZ EN LA MISMA L NEA TELEF NICA Para cancelar la secuencia de llamadas de alarma haga lo siguiente PASOS QUE DEBE REALIZAR 1 Realice la llamada al Sistema n mero de te...

Page 34: ...E LA RED TELEF NICA Si este Sistema causa da o a la red telef nica la compa a telef nica le notificar con anticipaci n que puede ser necesaria la suspensi n temporal del servicio Pero si el aviso con...

Page 35: ...lente El motor zumba pero la bomba no funciona 1 Bater a defectuosa 2 El impulsor est bloqueado 1 Verifique la bater a y reempl cela si el flujo es bajo o defectuoso 2 Desconecte la bomba retire la re...

Page 36: ...cionamiento de menos de 1 hora 1 Corte de energ a 2 Corte de energ a extendido 1 Notifique a la compa a de servicios p blicos 2 Prepare una bater a de repuesto Cambie la bater a 1 La bater a tiene poc...

Page 37: ...est configurado a 5 repiques 1 Haga una llamada al Sistema n mero de tel fono de la ubicaci n de la alarma deje sonar 3 tres veces cuelgue 2 Realice una segunda llamada al Sistema en 3 minutos el Sist...

Page 38: ...as garant as impl citas o no permiten las exclusiones o limitaciones de da os incidentales o consecuentes de manera que las limitaciones mencionadas anteriormente pueden no aplicarse en su caso Esta g...

Page 39: ...Notes Remarques Notas 39 Sp DF12VSM www blueangelpumps com...

Page 40: ...Notes Remarques Notas 40 Sp Manuel de Instrucciones y Lista de Piezas www blueangelpumps com...

Reviews: