6 FlexCoder
Instruction Manual
INPUT POWER:
+12VDC 2.2A Input power from external supply.
QAM RF OUT:
“F” connector for up to four (4) QAM RF outputs.
IP RESET:
When pushed and held for about 10 seconds, the encoder temporarily resets to the default IP address, Usernames
and Passwords as shipped from the factory (shown below). User settings are retained for viewing on the Admin Page.
IP address = 172.16.70.1
Username = Admin (case-sensitive)
Password = pass (case-sensitive)
NOTE:
The FlexCoder will revert to these user settings upon re-booting.
Remote CONTROL 100/1000:
RJ45 connector for 100/1000Base-T Ethernet interface for monitoring and configuring the unit. Only static IP address can be
assigned to this interface. The factory default value is 172.16.70.1.
DATA 1 GIGE:
RJ45 connector for 1000Base-T Ethernet (GIGE) interface for IP data (in/out).
ASI OUT:
User can select 1 TS for ASI Output.
ASI INPUT:
BNC connectors 1 to 4 for unencrypted ASI inputs.
8VSB/QAM INPUT:
Optional RF Input (6582 RFI)
INPUT STATUS LED:
LED indicate the input status as follows:
Green = Input is detected and has no errors
Red = Input with error (Communication with QAM or over temperature condition)
POWER:
LED is Green = DC power is detected.
LED is Off = DC power is not detected
Description:
Front panel connectors and indicators: