AQT8-QAM/IP
User Manual
CW Control:
Allows the user to switch the QAM output mode to CW (Continuous Waveform) which activates an
analog carrier at the selected channel’s center frequency comparable to the digital QAM output level. In CW
mode all 4 channels on the QAM output module will be on regardless of the “Output Control” setting. CW mode is
typically used when an analog signal level meter is used to measure the unit’s output level during installation and
servicing.
NOTE:
CW carriers are at center frequency and NOT at analog video carrier frequency.
Output Select:
Allows user to select TS stream for each QAM output. The options are: IP Out 1 through IP Out 8,
default IP and default RF (pass-through). Default IP/RF means that QAM1 will get TS from IP Out 1 or RF 1 (input),
QAM 2 will get TS from IP Out 2 or RF 2 (input, and so on)
NOTE:
When using any of the IP settings, the particular IP output must be "enabled" see Section 6.5.