31
5.8 How to replace a full BigBag (weight appr. 1000kg.)
Important note!! Make sure the operator in the cabin is aware of
the works in the rear the truck while performing this action!!!
For your safety an emergency switch is placed that cuts off the
complete system.
A:
Switch off the rotating valve with one of the green switches,
placed on the door of the top filter section.
The following message will occur on the touch screen.
B:
Release the spring loaded clamp by unlocking
the quick release clamp.
C:
Remove and close the funnel of the BigBag.
D:
Lift the pallet where the BigBag is placed on and park it in the rear of the truck
floor.
E:
Place a new BigBag on a new pallet, sleeve the funnel on, lock it with the clamp
and switch on the rotating valve again with the green switch.
NOTES:
-If the BigBag is sucked against the dust outlet, the Release valve can be used to reduce
the suction.
-The vibration motors can be used when the dust is not sliding down the hoppers.
-The Quick release clamp is fitted with an OPEN/CLOSE-sensor, as a safety measure to prevent unintentional
start-up without a BigBag secured in place.
-
BigBag 91 x 91 x 70 cm – Part number E06918
Left & Right Rotating valve
ON/OFF switches
Emergency shutdown
Vibration motors ON
Quick
release
clamp
Release
valve