background image

10

11

TO CHECK THE BATTERY VOLTAGE IN CHARGING MODE:

Press the battery voltage check button and the LCD screen will display the following:

  The digital display shows the current voltage of the connected battery for 10 seconds. During this period, 

pressing the battery voltage check button again will return the unit to charging mode. Pressing the alternator 

check button or the battery recondition button will have no effect. The unit will automatically return to 

charging mode after 10 seconds.

When disconnecting charger, disconnect AC cord, remove clamp from vehicle chassis, and then remove clamp 

from battery terminal.

Using the Alternator Check Function

Set up the battery charger and connect to the battery following steps 1 through 2 in the “Charging the Battery” 

section. 

PART 1

No Load (turn OFF all vehicle’s accessories): 

The battery must be fully charged before testing the 

alternator. Run the engine long enough to achieve normal idle speed and verify there is a no-load voltage.

  1. Press the alternator check button to start the check. The LCD screen will display the following to indicate the 

unit is analyzing the alternator:

  “Check” will flash, and the alternator icon and the gage without the pointer will light solid.

  2. If the unit detects that the alternator is good, the LCD screen will display the following:

  “Good”, the alternator icon and the gage without the pointer will light solid.

  3. If the unit detects that the alternator is out of typical voltage range, the LCD screen will display the following:

  The fault icon will flash; and the alternator icon, “ALT” and the gage without the pointer will light solid.

  4. Press the alternator check button again to stop the test.

PART 2

Under Load (accessories ON): 

Next, load the alternator by turning on as many accessories as possible 

(except for A/C and Defrost).

  1. Press the alternator check button to start the check. The LCD screen will display the following to indicate the 

unit is analyzing the alternator:

  “Check” will flash, and the alternator icon and the gage without the pointer will light solid.

  2. If the unit detects that the alternator is good, the LCD screen will display the following:

  “Good”, the alternator icon and the gage without the pointer will light solid.

  3. If the unit detects that the alternator is out of typical voltage range, the LCD screen will display the following:

  The fault icon will flash; and the alternator icon, “ALT” and the gage without the pointer will light solid.

  4. Press the alternator check button again to stop the test.

Notes:

 

All buttons except the alternator check button are disabled in alternator check mode.

 

The unit may detect that the alternator is out of typical voltage range because someone has added a number of accessory loads on 

the charging system, thereby increasing current demand from the alternator. MAKE SURE THAT THE ALTERNATOR IS RATED TO 

SUPPORT THE APPLICATION.

 

This check may not be accurate for every make, manufacturer and model of vehicle. Check only 12 volt systems.

When disconnecting the charger, disconnect AC cord, remove clamp from vehicle chassis, and then remove 

clamp from battery terminal. 

Reconditioning the Battery

Periodic reconditioning is recommended to maintain a battery’s optimum performance. Battery recondition 

sends a series of electrical pulses to break up the crystalline form of lead sulfate and turn these chemicals into 

useful battery electrolytes. The process will stop automatically after 24 hours. To stop the process sooner, press 

the battery recondition button a second time. More than 24 hours may be needed to restore performance on 

some batteries. If so, repeat the process.

  1. Set up the battery charger and connect to the battery following steps 1 through 2 in the “Charging the 

Battery” section.

  2. Press the battery recondition button. The LCD screen will display the following:

  The battery recondition indicator, the clamp icons, the battery icon and the gage without the pointer will light 

solid, the bars on the battery icon will change from solid to empty (top to bottom) repeatedly and the battery 

recondition icons will flash.

  3. To stop the reconditioning process, press the battery recondition button again. Pressing any other button 

during this process will have no effect.

IMPORTANT:

 If 5 cycles of reconditioning does not improve battery performance, discontinue and recycle the 

battery. The battery charger will go into charging mode after 24 hours automatically.

BC15_25_40BD_ManualENSP_010515.indd   10-11

1/5/2015   5:44:58 PM

Summary of Contents for BC15BD

Page 1: ...l Highway Suite 210 Boca Raton FL 33432 www Baccusglobal com 1 877 571 2391 28 BC25BD BC40BD BC15BD AUTOMATIC BATTERY CHARGER WITH ENGINE START INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE...

Page 2: ...re in this instruction manual before further use FIRST AID Skin if battery acid comes in contact with skin rinse immediately with water then wash thoroughly with soap and water If redness pain or irri...

Page 3: ...in this Instruction Manual Check battery charger and components periodically for wear and tear Return to manufacturer for replacement of worn or defective parts immediately PREPARING TO CHARGE 1 Be s...

Page 4: ...OF INJURY Follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use with this unit Review cautionary markings on this product and o...

Page 5: ...t the pointer will light Disconnect the charger and allow the charger to cool for several minutes Make sure there is adequate ventilation around the unit before attempting to charge again IMPORTANT Th...

Page 6: ...following Good the alternator icon and the gage without the pointer will light solid 3 If the unit detects that the alternator is out of typical voltage range the LCD screen will display the followin...

Page 7: ...manufacturer If you need assistance regarding accessories please contact the manufacturer at 1 877 571 2391 WARNING The use of any accessory not recommended for use with this appliance could be hazar...

Page 8: ...ucto LEA EL MANUAL ANTES DE DEVOLVER ESTE PRODUCTO POR CUALQUIER MOTIVO Si tiene una consulta o alg n inconveniente con su producto visite HTTP WWW BACCUSGLOBAL COM para obtener respuestas instant nea...

Page 9: ...no es un juguete Evite las condiciones ambientales peligrosas No utilice artefactos en zonas h medas o mojadas No utilice artefactos bajo la lluvia Almacene bajo techo Cuando no est en uso los cargado...

Page 10: ...nas Los veh culos que tienen sistemas computarizados incorporados pueden resultar da ados si la bater a del veh culo se arranca mediante puente Antes de arrancar mediante puente lea el manual del clie...

Page 11: ...la bater a ha sido retirada del veh culo siga estos pasos ADVERTENCIA Una chispa cerca de la bater a puede causar una explosi n Para reducir riesgo de una chispa cerca de la bater a 1 Verifique la pol...

Page 12: ...signo dentro del icono de la bater a y el cono de fallo destellar y los iconos de la pinza la icono de la bater a y el medidor sin el puntero se iluminan y una advertencia sonar hasta que las pinzas s...

Page 13: ...LA BATER A EN MODO DE CARGA Pulse el bot n de verificaci n de la bater a voltaje y la pantalla LCD mostrar lo siguiente La pantalla digital muestra la tensi n de la bater a conectada durante 10 segund...

Page 14: ...a de partida del motor o tra vez 3 Cuando se alcanza 00 sonar un pitido el icono de arranque del motor comenzar n a parpadear El veh culo est listo para comenzar 4 Haga girar el motor seg n las direct...

Reviews: