43
CHAPTER 6: SCSI Technical Information
•
DB(0 through 15,P,P1) (DATA BUS)
: Eight data-bit signals, plus a parity-bit
signal that form a data bus. DB(7) is the most significant bit and has the
highest priority during the Arbitration phase. Bit number, significance, and
priority decrease downward to DB(0). A data bit is defined as one when the
signal value is true and is defined as zero when the signal value is false. Data
parity DB(P) shall be odd.
Table 6-1. SCSI connector assignments single-ended (SE)
16-bit SCSI (wide)
Signal Name
Pin Number
Signal Name
Pin Number
Ground
1
-DB12
35
Ground
2
-DB13
36
Ground
3
-DB14
37
Ground
4
-DB15
38
Ground
5
-DBP1
39
Ground
6
-DB0
40
Ground
7
-DB1
41
Ground
8
-DB2
42
Ground
9
-DB3
43
Ground
10
-DB4
44
Ground
11
-DB5
45
Ground
12
-DB6
46
Ground
13
-DB7
47
Ground
14
-DBP
48