30
4 X 2 SCSI MATRIX SWITCH
f. Report Alarm Status:
command: <cr>//|a<cr>
report: //|axyz<cr> (xx- 8-bit hexadecimal value)
x: 1 = Over temperature
y: 1 = Power supply 2 failure
z = Power supply 1 failure
g. Report SCSI Bus Performance:
command: <cr>//|P<xy><cr>
report: //|P<aabb11223344<cr>
aa: hex 00-FF Port A
bb: hex 00-FF Port B
hex 00 = 0% Busy
hex FF = 100% Busy
h. SCSI bus Inactivity to SCSI report:
command: <cr>//|I<cr>
report: xxxx: hex inactive time in tenths of seconds
i. Yank on SCSI Reset line:
command: <cr>//|<AB1234Y><cr>
report: none
j. Disable Audible Alarm:
command: <cr>//|OA<x><cr>
x: 0= don’t disable
x: 1=disable alarm
report: none
Summary of Contents for SC122A