38
4 X 2 SCSI MATRIX SWITCH
5.13.3 S
ETSWITCH
U
TILITY
The setswitch.exe utility enables you to set switch parameters via the LAN port.
This utility is located on the diskette provided with your SCSI Switch. To change
switch settings and termination for an SCSI Switch: from a DOS prompt run
SETSWITCH.EXE from the diskette provided.
Usage:
setswitch [/?] [/i<IP Address>] [/c<Com Port>] [/b<baud rate>]
[/n<Switch Number>] [/h<holdoff>] [/x] [/t<Termination>]
[[/s]<SwitchSettings>] [/w<command>] [/r<command>]
Where:
/? = this message.
/i <IPAddress> = The IP address of the network-enabled SCSI Switch.
/c <Com Port> = The number of the Com Port to address (1 to 8;default=1).
/b <Baud Rate> = The baud rate for the com port (2400, 9600, 19200;
dflt=9600).
/n <Switch Number> = The number of the switch to change (1 to 32; default=1).
/h <holdoff> = SCSI Bus holdoff, in seconds. The SCSI Switch will not change
the switch settings on a bus until there has been inactivity the specified
number of seconds. Valid range is 0 to 25 seconds.
/x = Ignore SCSI Bus activity. Switch settings will be changed immediately.
/t <Termination> = Termination can be turned on or off for each port (A or B,
or 1 to 4). “A2NB3F” activates termination for ports A and 2 and, it
deactivates termination on ports B and 3. Termination on unspecified ports
will not be affected.
[/s]<Switch Settings> = The settings to be changed (/s is optional).
“A1B2NB1A2F” connects ports A1 and B2 and disconnects ports B1 and A2.
Switch settings on unspecified ports will not be affected.
[/w]<command> = <command> is sent to the switch with no parsing. Any
response from the switch is ignored.