![Black Box SC122A Manual Download Page 26](http://html1.mh-extra.com/html/black-box/sc122a/sc122a_manual_2761659026.webp)
23
CHAPTER 5: Configuration and Operation
5.3 Selecting Internal Terminator Power
On-board SCSI Switch terminators can be powered by internal 5-volt power or
externally from SCSI bus “termination power.”
Figure 5-1. Internal terminator power jumpers.
Table 5-1. Jumper settings for internal termination
E1-Port A
E5-Port 1
E7-Port 3
E2-Port B
E6-Port 2
E8-Port 4
NOTE
The standard factory default connects internal terminators to internal
5 volts.
5.4 Selecting External Terminator Power
The SCSI Switch can supply external terminator power via an internal resettable
fuse. This fuse supplies 1 amp at 5 volts to the termination power signal. The SCSI
Switch contains internal protection and will not be affected if other SCSI devices
provide terminator power.
Figure 5-2. External terminator power jumpers.
NOTE
Factory Default is “Enabled” on all ports.
E19-E28
E1-E8
Internal 5V
External
Termination
Power