Supervisor Terminal Emulations
Several terminal emulations are supported by the Sprint 2. When connection is made
between the terminal or PC and the rear panel port labelled
SUPERVISOR
, the following
screen will appear:
The terminal type or emulation in use should be selected by pressing the relevant number key
on the PC or terminal. The monitor will now show the basic configuration screen for the
multiplexer setup. On the Sprint 2 LANLink this is formatted as below. This display for the
Sprint 2 shows standard V.24 data channels only.
SPRINT 2 TDM
xxxxAE/x.xx
Mode
: RUN
Data Monitor
: RXD
Link Clock
: AUTO 64000
X.21 Carrier
: PRESENT
Residual : +24000
Option Cards
: NONE
Configure
:
>ACCEPT
Display Page
: LOCAL
COPY CHANNEL
: 1
2
3
4
5
6
7
X.21
RATE
: 4800
4800
4800
4800
4800
4800
4800
4800
TYPE
: SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
RX CLOCK
: INT
INT
INT
INT
INT
INT
INT
INT
TX CLOCK
: INT
INT
INT
INT
INT
INT
INT
INT
BITS/CHAR
:
PARITY :
RTS/CTS DLY
: 0ms
0ms
0ms
0ms
0ms
0ms
0ms
0ms
SIGNALS
: BOTH+
BOTH+ BOTH+ BOTH+ BOTH+ BOTH+ BOTH+
BOTH+
CHANNEL MODE : RUN
RUN
RUN
RUN
RUN
RUN
RUN
RUN
Use cursor keys to select parameter, SPACE/- to toggle
Configuration Display Layout
Please select terminal type from the following:
1 = VT52/HP2600
2 = ANSI/VT100/VT200
3 = ADDS
4 = ADM-3A
5 = HAZELTINE 1500
6 = NEWBURY 8009
7 = TELEVIDEO 912/920